The alarm will initially emit an intermittent beep which increases in duration, 

before progressing to a continuous beep, ending only when movement is 

detected again. The selected delay is indicative only and begins following  

an initial pause (approx. 15 seconds).

There are 8 function switches on the device which are normally turned ON 

(upwards) during set up.

Figure 2: Alarm delay rotary switch (the alarm delays shown are approximate)

Figure 3: Side view of Venner DruGuardian

 function switches

Alarm delay rotary switch

2.1.1

Function switches

2.1.2

ON (up)

OFF (down)

1

Alarm

Audible alarm is  

turned ON

Audible alarm is turned 

OFF, unit will still 

collect open/close and 

photographic data

2

Camera

Photos from the camera 

are stored on the image 

micro SD card

The camera is disabled 

and no photos from the 

camera are stored on 

the image micro SD card 

3

Data log

Door opening times and 

alarm data are stored on 

the data micro SD card

No information is  

stored on the data  

micro SD card 

4

Volume

Alarm volume set  

to Normal

Alarm volume low for 

quiet locations 

5

Re-program

Normal Operation

May be set to OFF for 

additional security 

6

Redundant

Normal operation 

Normal operation

7

Redundant

Normal operation 

Normal operation

8

Initial  

assessment

Normal operation

The alarm function is 

disabled for two weeks 

in order to obtain base 

line data. The alarm 

function automatically 

reactivates after the two 

week delay. 

Figure 4: Function switches 
NB: Setting switches 2 or 3 to OFF will reduce battery usage. 

The alarm delay rotary switch has 16 positions that determine the time delay 

before the alarm commences. Using the small screwdriver provided, rotate the 

switch until the dot is adjacent to the user required time delay. 

Operative switches

2.1

Operating instructions

2.

 7

 6

Содержание DruGuardian

Страница 1: ...Medical Singapore Pte Ltd 35 Joo Koon Circle Singapore 629110 www vennermedical com Venner Medical Technologies SA Osprey House Old Street St Helier Jersey JE2 3RG www vennermedical com en OPERATING...

Страница 2: ...s 5 2 1 1 Alarm delay rotary switch 6 2 1 2 Function switches 6 2 1 3 Security level switch 8 2 2 LED battery indicator 8 2 3 Using the device 9 3 Battery and charging 11 4 Service and maintenance 12...

Страница 3: ...exposure to light Venner DruGuardian records detailed time and alarm data while the wide angle camera captures images in front of the Venner DruGuardian facilitating identification of persons in the v...

Страница 4: ...photos from the camera are stored on the image micro SD card 3 Data log Door opening times and alarm data are stored on the data micro SD card No information is stored on the data micro SD card 4 Vol...

Страница 5: ...y Three security levels low medium or high may be set based on user requirement The battery indicator illuminates different LED colours which represents CAUTION Recharge the device when the Dim or Sol...

Страница 6: ...camera will be stored on the image micro SD card along with a time stamp and location cradle RFID code reading Contents from both micro SD cards can be uploaded onto www VennerDruGuardian com to gene...

Страница 7: ...nnocent persons VMSG will not be held responsible should incidents occur VMSG will not provide any guarantee of continuous uninterrupted function of the device or that images will be captured in an id...

Страница 8: ...t may contain materials which if disposed with general waste could be damaging to the environment Residents of the European Union must follow specific disposal or recycling instructions for this produ...

Страница 9: ...Venner Group of Companies This product is covered by patents and patent applications of the Venner Group of Companies in the US and other territories Visit www vennerdruguardian com intellectual prop...

Отзывы: