Venmar VJ61030SS Скачать руководство пользователя страница 5

5

3. PREPARE 

INSTALLATION

WARNING

!

Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. This 
range hood must be properly grounded. Turn off electrical power at service entrance before wiring. 

NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the retailer.

Make sure that the following items are included:

- Hood
- Micromesh 

filter

-  Curved glass panel (installed on the hood)
-  Decorative flue assembly (lower and upper flues)
-  Lower flue mounting bracket
-  Upper flue mounting bracket
-  Hood mounting bracket
-  6" Round adapter/damper
- Installation 

instructions

-  Parts bag:  2 x no. 8 x 1¼" mounting screws, 7 x no. 8 x 1½" mounting screws, 8 x no. 8 x 7/16" mounting screws, 9 drywall anchors
 

NOTE: If need be, discard extra screws.

Parts sold separately:

-  Ducts, elbows, wall and roof caps.
-  Optional flue extension for 10-ft. ceilings model no. 20366.

NOTE: During installation, protect countertop and/or cooktop.

4. WIRING 

INSTALLATION

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an 
escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must 
be plugged into an outlet that is properly installed and grounded.
Set the electrical power supply within the space covered by the decorative flue.

Position the outlet offset so that the power cord will not interfere with the round duct. 
Place the outlet at a maximum distance of 33

7

/

16

" from where the cord exits from 

the hood (see illustration at right). Make sure this does not interfere with a mounting 
bracket fastening area or with the decorative flue (where the flue touches the wall).

WARNING

!

Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions 
are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an 
extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.

HE0159

33

7

16

MAX

.

Содержание VJ61030SS

Страница 1: ...VE THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 8 AND 9 READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation Inc 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGIST...

Страница 2: ...rface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when...

Страница 3: ...orized service provider The unit removal and reinstallation works are under the customer responsibility and Venmar Ventilation Inc cannot be charged for them The duration of any implied warranty is li...

Страница 4: ...T ROOF CAP 6 ROUND ELBOW WALL CAP HOOD DECORATIVE FLUE HH0195A 26 MINIMUM ABOVE COOKING SURFACE 30 FOR GAS RANGE 2 MEASURE INSTALLATION 26 MINIMUM ABOVE COOKING SURFACE 30 FOR GAS RANGE STANDARD 36 H...

Страница 5: ...4 WIRING INSTALLATION GROUNDING INSTRUCTIONS This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for t...

Страница 6: ...e bracket point down Use the upper flue mounting bracket as a template to mark the position of its screws Drill both screw holes using a 5 16 drill bit Insert the included drywall anchors into the dri...

Страница 7: ...s sufficent Install the lower flue bracket to its flue using 2 no 8 x 7 16 mounting screws ensure that the slots point up Fig 3 6 Carefully place both flues into the recessed area of hood top NOTE Sli...

Страница 8: ...stall the light bulb cover CAUTION Do not touch replacement bulb with bare hands 11 OPERATION HC0068 1 2 1 Blower ON Speed increase push button 3 Delay setting push button 2 Blower OFF Speed decrease...

Страница 9: ...lean the filter Let it dry and reinstall it Grease filter is dishwasher safe Clean all metal filter in the dishwasher using a non phosphate detergent Discoloration of the filter may occur if using pho...

Страница 10: ...esult in premature failing Venmar Ventilation Inc also recommends to contact a Venmar certified service depot for all replacement parts and repairs KEY NO PART NO DESCRIPTION QUANTITY 1 08486 BRACKET...