Before proceeding to the installation, check the contents of the box. If items are missing or 
damaged, contact the manufacturer.

Make sure that the following items are included:

VCQLA1 Series

(1) 3¼” 

X

 10”

D

AMPER

 A

SSEMBLY

(1) 7” R

OUND

D

UCT

 C

ONNECTOR

(1) P

ARTS

 B

AG

*** C

ONTAINING

:

(6) N

O

. 8 

X

 5/8”

RD. HD.

W

OOD

 S

CREWS

(2) I

NSTALLATION

 B

RACKETS

**

FOR

 

FRAMED

 

CABINET

(2) I

NSTALLATION

 B

RACKETS

**

   

FOR

 

FRAMELESS

 

CABINET

(1) T

EMPLATE

 

FOR

 

DUCTING

  (

PRINTED

 

BOTH

 

SIDES

)

(4) N

O

. 8-18 

X

 1/2”

M

ETAL

 S

CREWS

 

WITH

(4) W

ASHERS

(6) N

O

. 8 

X

 1/2”

C

OUNTERSUNK

W

OOD

 S

CREWS

 

EZ1 C

OMPONENTS

C

L

A

B

Apoyar este borde contra la pared de atrás

Place this edge against back wall

VERTICAL EXHAUST

S

A

A

V

RTICAL EX

= 3¼” x 10”

= 3¼” x 14”

RECTANGULAR DUCTING

7” ROUND DUCTING

OR

Use this template for marking;  do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

= 3¼ po x 10 po

= 3¼ po x 14 po

CONDUIT RECTANGULAIRE

CONDUIT ROND DE 7 PO

OU

= 3¼ pulg. x 10 pulg.

= 3¼ pulg. x 14 pulg.

CONDUCTO RECTANGULAR

CONDUCTO REDONDO

DE

 7 PULG.

O

Appuyer ce bord au mur arrière

Utiliser ce gabarit pour marquer vos repères;  ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados;  no trate de cortar el
agujero del conducto a través de la plantilla.

NOTA: To be translated in Spanish.

MARK WHERE INDICATED 

FOR

 THE APPROPRIATE SIZE DUCT OPENING

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON 

LE

 FORMAT DE CONDUIT UTILISÉ

TITLE TO BE TRANSLATED IN SPANISH

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

4¼”

10½”

14½”

8”

7½”

C

C

C

Bend template along graduated
scale when installing to framed
cabinet.

Pour une installation sous une
armoire à fond en retrait, utiliser les
lignes pour mesurer l’épaisseur du
décalage causé par le mur de 
l’armoire et plier le gabarit en 
conséquence.

To be translated in Spanish.

** F

IND

 EZ1 B

RACKETS

 

ATTACHED

 

INSIDE

 

OF

 

HOOD

(2) G

REASE

 F

ILTERS

*** F

IND

 

PARTS

 

BAG

 

INSIDE

 

OF

 

HOOD

* F

IND

 

INSIDE

 

ONE

 

PACKAGING

STYROFOAM

 

OF

 

HOOD

Содержание VCQLA1 Series

Страница 1: ...WWW VENMAR CA Serial number 99045657 005A WWW VENMAR CA RANGE HOOD Series VCQLA1 INSTALLATION USE AND CARE MANUAL...

Страница 2: ...ing Installation 8 20 Recommended Tools and Accessories for Installation 8 Install Ductwork Ducted Installations Only 8 Contents 9 Prepare the Hood 10 12 Prepare the Hood Location 13 EZ1 Person Instal...

Страница 3: ...fficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guidelines a...

Страница 4: ...nd you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen F...

Страница 5: ...beep will be emitted at the first touch and again at the end of the 3 second hold The blower will continue to operate for 10 minutes at this setting During this time the sensor corresponding to the ac...

Страница 6: ...lighting and lasting up to 25 times as long as a standard bulb While they are available as service parts these modules are designed to last the life of the hood FILTER CLEANING REMINDER When it is tim...

Страница 7: ...WHEELS The center of the fan wheels should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with w...

Страница 8: ...e hood Install Ductwork Ducted Installations Only SOFFIT 18 MIN 24 MAX ABOVE COOKING SURFACE CABINET 3 X 10 DUCT FOR HORIZONTAL DISCHARGE WALL CAP ROOF CAP 3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARG...

Страница 9: ...puyer ce bord au mur arri re Utiliser ce gabarit pour marquer vos rep res ne pas tenter de d couper le trou pour le conduit travers le gabarit NOTE Les d coupes incluent le jeu n cessaire l installati...

Страница 10: ...ger cup remove the grease filters from the hood by pushing down and tilting filters out 7 ROUND DUCT PLATE 2 SCREWS 1 2 3 4 5 6 7 4 Using a 11 32 nutdriver or socket remove the lock nut retaining the...

Страница 11: ...Remove the parts bag taped on the inner back of hood near the left corner Remove the EZ1 brackets from inside the hood by cutting off the tie wrap Discard the tie wrap 6 Remove Electrical Power Cable...

Страница 12: ...ter ductwork the 7 round duct plate can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10...

Страница 13: ...10 3 x 14 RECTANGULAR DUCTING 7 ROUND DUCTING OR Use this template for marking do not attempt to cut out the ducting hole through it NOTE These cutouts are clearance holes they do not need to be the e...

Страница 14: ...ws Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at B location...

Страница 15: ...ine on the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align outside edge of the bracket to marked line keeping the rear end edge leaning on the wall Use a p...

Страница 16: ...REAR HOLES A and B While holding the hood run the house power cable into the hood through the strain relief previously installed in step 6 on page 11 4 Unhook the rear holes from the brackets and han...

Страница 17: ...s per side in the slots as shown in insets on illustration below 8 For frameless cabinet secure the hood to the cabinet using four 4 no 8 x 5 8 round head wood screws screws and washers included in pa...

Страница 18: ...ACCESS HOLE 5 5 CENTER LINE ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 9 47 16 CABINET BOTTOM REAR HOOD MOUNTING SCREWS 2 12 30 HOOD 15 36...

Страница 19: ...g screw heads are engaged in narrow end of keyhole slots in top of hood Tighten screws securely and maintain a hold on the hood until completing step 3 3 Secure the hood to the cabinet using two 2 no...

Страница 20: ...on page 10 Pay attention to screw 1 location from back of hood point of view it must be located on left side of the lock nut see inset WARNING Risk of electric shock Electrical wiring must be done by...

Страница 21: ...se filters removed in step 3 page 10 under Prepare the Hood Non ducted Installation Only Purchase two non ducted filters from your local distributor or retailer see product specification label for fil...

Страница 22: ...High W J8 1 2 3 4 5 3 4 5 6 7 1 2 1 2 3 4 5 3 2 1 4 Control Board W BK G Y W PP W BK BK BK BK W Fuse 5A 2 3 4 5 1 1 2 3 4 5 BK O 120 BL 88 PP 60 PN 45 Y 10 W W 5 4 3 2 1 6 User interface 1 2 1 2 3 4...

Страница 23: ...SS WITH AUTOTRANSFORMER AND FUSE 1 1 1 1 S97020360 PARTS BAG INCLUDING 4 METAL SCREWS NO 8 18 X 1 2 4 WASHERS 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1 1 1 1 S97020466...

Страница 24: ...ct or replacement parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part...

Отзывы: