Venmar PRO225 Скачать руководство пользователя страница 20

I

f

 

you

 

thin

your

 

unit

 

is

 

malfunctioning,

 

chec

some

 

of

 

the

 

followings

:

8.

TROUBLESHOOTING

1.

PR

O

BLE

M

S

TRY

 

T

HI

S...

The

 

LED

 

of

 

the

 

integrated

 

control

 

is

blin

k

ing

 

red.

There

 

is

 

a

 

problem

 

with

 

the

 

e

x

haust

 

motor.

 

The

 

unit

 

is

OFF

.

 

Contact

 

your

 

installer.

2.

The

 

LED

 

of

 

the

 

integrated

 

control

 

is

blin

k

ing

 

green.

There

 

is

 

a

 

problem

 

with

 

the

 

thermistor.

 

The

 

unit

 

is

 

still

wor

k

ing,

 

but

 

will

 

defrost

 

frequently.

 

Contact

 

your

 

installer.

3.

The

 

LED

 

of

 

the

 

integrated control

 

is

 

blin

k

ing

 

amber.

There

 

is

 

a

 

problem

 

with

 

the

 

motori

z

ed

 

damper.

 

The

 

unit

 

is

OFF

.

  F

or

 

a

 

2

½-

hour

 

period,

 

the

 

unit

 

will

 

try

 

to

 

reset

 

the

damper

 

at

 

every

 

30

 

minutes.

 

After

 

2

½

hours,

 

if

 

the

 

problem

 

is

 

not

 

solved,

 

the

 

unit

 

stops

 

trying

 

to

 

reset

damper.

Contact

 

your

 

installer.

Chec

control

 

wiring.

4

.

The

 

integrated

 

control

push

 

button

 

does

 

not

wor

k

.

The

 

30

-

second

 

boot

 

sequence

 

is

 

not

 

completed.

 

See

Booting

 

Sequence

 

on

 

page

 

1

4

.

5.

Nothing

 

wor

k

s.

See

 

if

 

the

 

unit

 

is

 

plugged

 

in.

See

 

if

 

the

 

unit

 

is

 

receiving

 

power

 

from

 

the

 

house

 

circuit

brea

k

er

 

or

 

fuse.

6

.

Condensation

 

on

 

windows.

 

(

Air

 

too

 

humid.

)

Ad

j

ust

 

the

 

humidity

 

control

 k

nob

 

as

 

per

 

instructions

 (

see

Section

 6)

.

Leave

 

curtains

 

half

-

open

 

to

 

allow

 

air

 

circulation.

Store

 

all

 

firewood

 

in

 

a

 

close

 

room

 

with

 

a

 

dehumidifier

 

or

in

 

a

 

well

 

ventilated

 

room,

 

or

 

store

 

the

 

wood

 

outside.

• K

eep

 

the

 

temperature

 

in

 

your

 

house

 

above

 

18

°

C

 (64°F)

.

Set

 

the

 

unit

 

at

 

high

 

speed

 

during

 

activities

 

generating

e

x

cess

 

humidity

 (

family

 

gatherings,

 

e

x

tra

 

coo

k

ing,

 

etc.

)

.

7.

Air

 

too

 

dry.

Temporarily

 

use

 

a

 

humidifier.

Using

 

integrated

 

control,

 

set

 

the

 

unit

 

at

 

low

 

speed.

PR

O

250

 

unit

 

only

 (

with

 

Bree

z

e

 

control

)

-

Do

 

not

 

ad

j

ust

 

your

 

humidity

 

control

 

below

 -

20

°

C

 (-4°F)

.

-

Set

 

the

 

unit

 

at

 

minimum

 

speed

 (MI

N.

)

.

 

-

Temporarily

 

switch

 

to

 

the

 

AUT

OM

AT

I

C

 

mode.

PR

O

225

 

unit

 

only

 (

with

 

1113

control

)

-

Set

 

the

 H

umidity

 

level

 

selector

 

below

 

30

% (

see

 6

.2

 

on

page

 

18

)

.

8.

Air

 

too

 

cold

 

at

 

the

 

air

supply

 

grille.

• M

a

k

e

 

sure

 

the

 

outside

 

ports

 

are

 

not

 

bloc

k

ed.

• H

ave

 

the

 

unit

 

defrost

 

system

 

chec

k

ed.

• I

nstall

 

a

 

duct

 

heater.

Using

 

integrated

 

control,

 

set

 

the

 

unit

 

at

 

low

 

speed.

PR

O

250

 

unit

 

only

 (

with

 

Bree

z

e

 

control

)

-

Set

 

the

 

unit

 

at

 

minimum

 

speed

 (MI

N.

)

.

20

Содержание PRO225

Страница 1: ...NS Venmar Ventilation inc 550 Lemire Blvd Drummondville QC Canada J2C 7W9 www venmar ca VB0121 These products earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resou...

Страница 2: ...extension cord 9 Do not install in a cooking area or connect directly to any appliances 10 Do not use to exhaust hazardous or explosive materials and vapors 11 Do not run any air ducts directly above...

Страница 3: ...ANCE 19 7 1 Regular Maintenance 19 7 2 Annual Maintenance 19 8 TROUBLESHOOTING 20 TABLE OF CONTENTS Congratulations You have made an excellent choice The operating principle of your Heat Recovery Vent...

Страница 4: ...out the following operations During winter these units recover the heat contained in the stale air before it is exhausted and transfer it to the fresh air drawn from the outside reverse process in su...

Страница 5: ...diagrams Please note that the stale air never mixes with the fresh air DURING AIR EXCHANGE VF0045 FRESH AIR FROM OUTSIDE FRESH AIR TO BUILDING STALE AIR FROM BUILDING STALE AIR TO OUTSIDE DURING DEFRO...

Страница 6: ...side temperature 5 C 23 F to 27 C 17 F or coldest and will increase in frequency as the temperature decreases Its duration is of 7 or 10 minutes 8 Adjusting tools 2 adjust the dampers one on each side...

Страница 7: ...NTRAL STAIRWAY CLOSED IN BASEMENT STAIRWELL 2 STORIED HOUSE CENTRAL STAIRWAY CLOSED IN BASEMENT STAIRWELL Basement installation kit no CH30115 Basement installation kit no CH30115 with one additional...

Страница 8: ...in is close by use a pail to collect run off Away from hot chimneys electrical panel and other fire hazards Allow for a power source standard 3 prong grounding outlet Use the 4 chains and springs from...

Страница 9: ...he stairway as possible and in such a way that the air circulates in all the lived in spaces in the house If a register is installed in the kitchen it must be located at least 4 feet 1 2 m from the ra...

Страница 10: ...ase refer to your local building code 0 METAL TRANSITION B FRESH AIR TO BUILDING DUCT AND EXHAUST AIR FROM BUILDING DUCTS Fresh air to building duct See point A above Fresh air to building duct only E...

Страница 11: ...resh air to building Distribution d air frais 1 Use the following procedure for connecting the insulated flexible ducts to the unit ports exhaust to outside and fresh air from outside a Pull back the...

Страница 12: ...LE AIR EXHAUST PORT FRESH AIR INTAKE PORT 6 1 8 M 6 1 8 M 18 457 MM 18 457 MM 6 152 MM 18 457 MM OPTIONAL LOCATION 4 9 CONNECTING INSULATED DUCTS TO EXTERIOR PORTS For each exterior port using a jig s...

Страница 13: ...CONNECTING THE DRAIN Make a water trap loop in the tube to prevent the unit from drawing unpleasant odors from the drain source Make sure this loop is located OVER the T as shown Run the tube to the f...

Страница 14: ...onic module inside the unit 0 BOOT SEQUENCE The unit boot sequence is similar to a personal computer boot sequence Each times the unit is plugged after being unplugged or after a power failure the uni...

Страница 15: ...NAL CONNECTOR 5 2 3 20 MINUTE LIGHTED PUSH BUTTON OPTIONAL AUXILIARY CONTROL PRO250 PRO 225 NO C NC I OC OL Y R G B VE0185 ON 5 2 CONTROLS CONNECTION TO THE UNIT CONT D 5 2 2 11136 MAIN CONTROL PRO225...

Страница 16: ...an also be controlled using the included main controls the Breeze main control for the PRO250 unit and the 11136 main control for the PRO225 unit WARNING Always disconnect the unit before making any c...

Страница 17: ...ill turn OFF for the first 40 minutes and operate on air exchange mode with the outside in low speed during the last 20 minutes of the hour The air exchange indicator will be lit If the humidity contr...

Страница 18: ...or the present humidity level precision of 5 Turn the selector to the right of the click to lower the humidity level in the house This will initiate the air exchange mode on your ventilation system an...

Страница 19: ...necessary Also check during very cold weather because ice may grow on the screen located at the exterior intake hood WARNING Dangerous voltage may be present During maintenance and repairs the unit mu...

Страница 20: ...unit is receiving power from the house circuit breaker or fuse 6 Condensation on windows Air too humid Adjust the humidity control knob as per instructions see Section 6 Leave curtains half open to a...

Страница 21: ...be used in a building as defined below Building All structures zoned and or erected for the act process or art of human or animal habitation and or the storage or warehousing of goods Residential use...

Страница 22: ...22 This page is left empty...

Страница 23: ...stionnaire within 10 days of your purchase to the address below Note that only the questions on this side of the page are mandatory Your answers will be used for market research studies and reports an...

Страница 24: ...e probl mes sp ci ques Autres Pr cisez SVP Qui a install l appareil Constructeur de la maison Installateur recommand Ami membre de la famille Entrepreneur Vous m me Veuillez lire la liste des crit res...

Отзывы: