Venmar HEPA 3100 Скачать руководство пользователя страница 18

6.1 M

AIN

S

WITCH

All units are equipped with a 3-position main switch, located on the front panel. 

6.2 40415 

AND

40425 W

ALL

C

ONTROLS

D

ESCRIPTION

The included wall control is 40415 (intented for HRV 2600, HEPA 3100 and HEPA 4100 units only) or 40425 control (intented for 
HR 2.6 and HF 3.1 units only). The wall control is in OFF mode when power is applied for the first time. The mode does not change
following a power failure.

40415

CONTROL OR

40425

CONTROL

6.3 O

PERATING

40415 / 40425 C

ONTROLS

The wall controls 40415 and 40425 provide 5 operation modes. Press the 

Mode

button to select the desired mode.

6. CONTROLS

OFF: 

U

NIT IS OFF AND

DOOR IS

UNLOCKED

.

NORMAL/REMOTE:
U

NIT IS OPERATING ON

NORMAL SPEED

. T

HIS IS

THE RIGHT POSITION

WHEN A WALL CONTROL

IS USED

.

BOOST:

U

NIT IS OPERATING

ON HIGH SPEED

.

VC0098

VC0053

- 18 -

I

LLUMINATES IN ALL MODES

EXCEPT

OFF

MODE

.

F

ILTER AND PREFILTER MAINTENANCE

LED.

F

LASHES

WHEN IT IS TIME TO REPLACE

PREFILTER AND WASH CORE FILTERS

.

S

EE

B

IANNUAL

M

AINTENANCE IN

S

ECTION

7.1.

L

IGHTS UP

WHEN IT IS TIME TO REPLACE

FILTER AND PREFILTER AND WASH CORE FILTERS

.

S

EE

A

NNUAL

M

AINTENANCE

S

ECTION

7.2.

The unit exchanges air 

at normal speed. 

The outdoor 

temperature* is displayed.

The unit exchanges air 

at high speed. 

The outdoor 

temperature* is displayed.

The unit recirculates air. However,

every 20 minutes the unit

exchanges air for 

2.5 minutes so that it can obtain

a reading of the outdoor temperature*.

The unit operates on a 60-minute cycle. 

For the first 40 minutes, the unit recirculates

air or is off (See configuration parameter 2).

For the last 20 minutes, it exchanges air.

However, if the outdoor temperature* is too

high or too low (see configuration 

parameters 3 and 4), the unit recirculates

air during the last 20 minutes.

N

ORMAL

M

ODE

(M

IN

)

B

OOST

M

ODE

(M

AX

)

R

ECIRCULATION

M

ODE

(R

E

-

CIRC

)

O

FF

M

ODE

The unit is off. 

The outdoor temperature*

is not displayed.

Off in 

Auto mode

Air exchange in

Auto mode

Air recirculation

in Auto mode

A

UTOMATIC

M

ODE

(A

UTO

)

P

RESS THIS BUTTON TO

ACCESS CONFIGURATION PARAMETERS

(

SEE SECTION

6.4).

• P

RESS EITHER BUTTON TO CHANGE

CONFIGURATION SETTING

(

SEE SECTION

6.4).

• P

RESS BOTH BUTTONS TO RESET THE FILTER

COUNTER OR PREFILTER COUNTER

.

P

RESS THIS BUTTON TO

SWITCH MODE

(

SEE

S

ECTION

6.3).

* The outdoor temperature reading is taken from the unit 

FRESH AIR

FROM OUTSIDE port; due to the lenght of the insulated duct, the reading
is slightly different from the real outside temperature.

Содержание HEPA 3100

Страница 1: ...OMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 18 TO 21 READ AND SAVE THESE INSTRUCTIONS 04313 rev G M O D E L S VB0064 HEPA 3100 HF 3 1 HEPA 4100 HRV 2600 HR 2 6 Patents pending NOTES 1 HRV 260...

Страница 2: ...4 Installation must be done in accordance with all applicable codes and standards including fire rated construction codes and standards 5 This unit is not designed to provide combustion and or diluti...

Страница 3: ...ANG THE UNIT 11 5 3 PLANNING OF THE DUCTWORK 12 5 4 INSTALLING NON INSULATED DUCTS AND REGISTERS 12 14 5 4 1 STAND ALONE SYSTEM 12 13 5 4 2 CENTRAL DRAW POINT 13 14 5 4 3 RETURN TO RETURN 14 5 5 INSTA...

Страница 4: ...Fresh filtered air is supplied by the register located in the lowest liveable level See figure at right 1 1 2 CENTRAL DRAW POINT CONNECTION TO A FORCED AIR SYSTEM VH0040 ALL UNITS For this type of ins...

Страница 5: ...E BISMARCK SALT LAKE CITY ST PAUL DES MOINE S MADISON HARRISBURG SACRAMENTO DENVER TOPEKA DETROI T INDIANAPOLIS SANTA FE SPRINGFIELD OKLAHOMA CITY PHOENI X COLUMBUS NASHVILLE ATLANTA BATON ROUGE AUSTI...

Страница 6: ...of the forced air unit To avoid cross contamination and achieve the highest efficiencies the forced air system blower must always be ON See figure below NOTE Home with multiple forced air systems shou...

Страница 7: ...e ductwork radius turn 8 203 mm VD0118A 8 222 mm 9 248 mm The joist opening needed to install the Tandem tansition included in both installation kits must be 9 248 mm minimum Also the maximum height o...

Страница 8: ...main switch etc Inspect the interior of the unit for damage Ensure that blower assembly heat recovery core insulation dampers MERV8 filter HRV 2600 or HR 2 6 units only prefilter and HEPA filter HEPA...

Страница 9: ...ront module onto the back plate and tighten the locking screw CAUTION Failure to comply with the following can cause erratic operation of the unit Never install more than one optional wall control per...

Страница 10: ...ing the small hole previously done From the top right front hole of the unit pull on the wire VO0019 VD0088 4 WALL CONTROL INSTALLATION CONT D 10 In order to access the unit PCB terminals remove the s...

Страница 11: ...NT THE PORTS ON THE UNIT Mount the 8 oval ports and the 5 to 6 oval ports on the top of the unit using the screws provided in the hardware box 4 screws 8 x 3 4 long per port See figure beside NOTE All...

Страница 12: ...ible air circulation Keep in mind that the filtered air register must be located as far as possible from the stale air register If desired you can install another register sold separately Install the...

Страница 13: ...e System described in point 5 4 1 Fresh Filtered air ductwork Return side connection HRV 2600 AND HR 2 6 UNITS ONLY Locate the opening for fresh filtered air ductwork on the forced air unit at a minim...

Страница 14: ...S 1 1 3 AND 1 2 2 Fresh Filtered air ductwork Return side connection Same as for Central Draw Point described in point 5 4 2 Stale air ductwork Return side connection ALL UNITS Locate the stale air du...

Страница 15: ...the vapor barrier over the insulation 4 Apply duct tape gently to the joint in order to make an airtight seal See figures below Identify each insulated duct For fresh air from outside duct use the blu...

Страница 16: ...exterior hood must be installed at a minimum distance of 18 inches 457 mm from the ground See illustration beside 5 6 3 CONNECTING TANDEM TRANSITION TO THE DUAL EXTERIOR HOOD 1 Using a jig saw cut a 6...

Страница 17: ...e 2 plastic drain fittings 1 using the gaskets 2 and nuts 3 as shown Close the door VO0027 27 686 mm 7 178 mm 3 Cut 2 sections of plastic tubing one 7 178 mm long and one 27 686 mm long and attach the...

Страница 18: ...TION 7 2 The unit exchanges air at normal speed The outdoor temperature is displayed The unit exchanges air at high speed The outdoor temperature is displayed The unit recirculates air However every 2...

Страница 19: ...OLS CONT D MENU PARAMETER OPTIONS DEFAULT DESCRIPTION NUMBER SETTING 1 TEMPERATURE FORMAT C F C SELECTS BETWEEN C AND F DISPLAY 2 AUTO MODE OPERATION RE OF RE SELECTS BETWEEN AIR RECIRCULATION RE AND...

Страница 20: ...nd the filter cartridge from the unit NOTE To remove the filter cartridge pull on its tabs item 3 1 Heat Recovery Core 2 Energy recovery Core 3 Filter Cartridge Tabs 4 Using your thumbs push on the pr...

Страница 21: ...filter maintenance LED simultaneously press both and buttons for 1 second 7 2 ANNUAL MAINTENANCE ESSENTIAL Perform this maintenance when the Filter Maintenance LED stays ON HRV 2600 AND HR 2 6 UNITS...

Страница 22: ...ly or not at all 5 Light indicators on wall control Check if the unit main switch is in Normal Remote position are flashing every second Check wall control wiring 6 Wall control screen indicates E1 Ch...

Отзывы: