3. M

AINTENANCE

 

(

CONT

D

)

 3.1 

Q

UARTERLY

 M

AINTENANCE

 

(

CONT

D

)

7

Always hold the core when rotating the 
two core retainers; failure to do so will 
cause the core to fall out.

    WARNING

!

 Lift both foam filter brackets 

 and 

 

remove the foam filters from the core. 

 

While holding the core, rotate the 2 core 

 retainers 

 and slide out the core from 

 the 

unit.

VD0177

  Clean the inside walls of the unit with a clean damp cloth, then wipe with a clean dry one.

  Wash the 2 core filters under hot water with mild soap. Rinse thoroughly and let dry 

 

completely before reinstalling on the core.

  Remove the dust on the core using a vacuum cleaner and a soft brush attachment.

Once the core reinstalled in the unit, always rotate both core retainers to their 
initial position; failure to do so will cause the core to fall out.

    WARNING

!

  Slide the core in the unit. Secure the 

 

core by rotating both core retainers to 

 

their initial position.

VB0078

VB0078

NOTE:  Once the core reinstalled in the 
 

unit, the arrows (circled in picture 

 

below) on its sticker label must be

 

pointing towards the unit motors.

  Reinstall both foam filters and secure them to the core by pulling down the 2 foam 

 

filter brackets. Reinstall the door.

  Close the door and plug the unit.

 

NOTE: The unit will return to its previous setting after a 30-second delay for boot 

  

sequence.

 3.2 

A

NNUAL

 M

AINTENANCE

Do the same operations as the Quarterly Maintenance (Section 3.1). Then, clean the 
exterior hood(s).

Содержание AVS Constructo 1.0 HRV

Страница 1: ...eeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA They meet ENERGY STAR requirements only when used in Canada 21785 rev 02 VB0203 AVS C12 ERV Top ports model no...

Страница 2: ...OFF for a few hours Do not use your unit during construction or renovation of your house or when sanding drywall This type of dust may damage your system Since the electronic control system of the uni...

Страница 3: ...LESHOOTING 8 1 DEFROSTING MODE When the outdoor temperature is below 5 C 23 F heat or energy recovery creates frost in the core To maintain its proper operation the unit is programmed to defrost its c...

Страница 4: ...s deux vis pour ouvrir le compartiment lectrique Pour retirer compl tement le d tacher de son fil de r tention int rieur No light OFForremotecontroled Amber light LOW speed Green ligh HIGH speed Blink...

Страница 5: ...ing the motorized damper position Once the motorized damper position completely set the RED light turns off and the booting sequence is done NOTE No command will be taken until the unit is fully boote...

Страница 6: ...dentify the inner parts of your unit VB0078 HRV core Foam filter brackets Core retainers Core foam filters ERV core Foam filter brackets Core retainers Core foam filters VB0077 3 1 QUARTERLY MAINTENAN...

Страница 7: ...ner and a soft brush attachment Once the core reinstalled in the unit always rotate both core retainers to their initial position failure to do so will cause the core to fall out WARNING Slide the cor...

Страница 8: ...r installer 8 The LED of the integrated control is blinking GREEN There is a problem with the thermistor The unit is still working but will defrost frequently Contact your installer 9 The LED of the i...

Отзывы: