CONGRATULATIONS! You have made an excellent choice!

We have prepared this User Guide especially for you. Please read it carefully to ensure you obtain full benefits from your
Heat Recovery Ventilator unit.

1.0

UNIT DESCRIPTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

1.1 S

PECIFICATIONS

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.0

FUNCTION OF THE HEAT RECOVERY VENTILATOR  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.1 H

EAT

R

ECOVERY

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2.2 D

EFROSTING

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.0

CONTROLS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6

3.1 I

NTEGRATED

C

ONTROL

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.1.1 B

OOT

S

EQUENCE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.2 O

PTIONAL

M

AIN

W

ALL

C

ONTROLS

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.2.1 L

ITE

-T

OUCH

C

ONSTRUCTO

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.2.2 C

ONSTRUCTO

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

3.3 O

PTIONAL

A

UXILIARY

C

ONTROLS

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

3.3.1 D

EHUMIDISTAT

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

3.3.2 20-M

INUTE

L

IGHTED

P

USH

B

UTTON

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

3.3.3 60-M

INUTE

M

ECHANICAL

T

IMER

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

4.0

MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

4.1

R

EGULAR

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

4.2

P

ROLONGED

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

5.0

TROUBLESHOOTING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

TABLE OF CONTENTS

2

1.

Some activities create dust or vapors which may damage your unit. You must, therefore, turn off and unplug 
your unit in the following situations:
• major renovation work

• housing construction

• sanding (e.g. gypsum joints, etc.)

• varnishing

2.

During heavy snow storms, turn off the unit to avoid problems caused by snow penetration, even if it is 
equipped with anti-gust intake hood.

3.

Power disturbances or very short power failures may cause the electronic control microprocessor to malfunction.
If it does, disconnect the power plug from the outlet and wait approximately 30 seconds, then plug it back in 
to resume operation.

About this Guide

This guide uses the following symbols to emphasize particular information:

NOTE: Indicates supplementary information needed to fully complete an instruction.

WARNING

Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of
death.

!

CAUTION

CAUTION

Denotes an instruction which, if not followed, may severely damage the unit and/or its components.

Содержание CONSTRUCTO 1.5

Страница 1: ...USER GUIDE MODELS CONSTRUCTO 1 5 CONSTRUCTO 2 0 READ AND SAVE THESE INSTRUCTIONS 08055 rev A VB0109...

Страница 2: ...unit You must therefore turn off and unplug your unit in the following situations major renovation work housing construction sanding e g gypsum joints etc varnishing 2 During heavy snow storms turn o...

Страница 3: ...tem can also operate on its own Units equipped with a heat recovery core can reduce ventilation costs in winter The unit draws the heat from the stale air and humid air before it is released and uses...

Страница 4: ...e rest of the booting sequence During this RED light phase the unit is checking and resetting the motorized damper position Once the motorized damper position completely set the RED light turns off an...

Страница 5: ...windows after using METHOD 1 for at least 1 month As ventilation needs vary from one house to another depending on cooking habits frequency of showers washing window design etc an adjustment based on...

Страница 6: ...llutants Purpose To eliminate excess humidity produced by showers or other periodic activities producing pollutants Press once to activate the push button The unit will operate on high speed for 20 mi...

Страница 7: ...setting after a 30 second delay for boot sequence Intake hood Regularly check the screen in the exterior intake hood and clean when necessary Also check during very cold weather because ice may build...

Страница 8: ...erate the unit at low speed MIN or in intermittent mode with Lite Touch Constructo Have the system s balancing checked Have the unit s defrosting system checked Install a duct heater 5 The LED of the...

Отзывы: