ATX2/S    PIEZOELECTRIC INDOOR SIREN WITH BUILT

–IN TRANSCEIVER TO CONTROL UP 

TO 8 OUTDOOR WIRELESS SIRENS. 

 
 
General Description 

 
Piezoelectric siren with an integrated transmitting section able to control up to 

8 wireless sirens

 and a receiving section 

able to manage all information coming from the memorized sirens. The transmitting section consist in two control inputs 
(

alarm input and on/off input) 

to be connected to the main , a button (

P1) 

which transmits continuously, if pressed,  

the codes to be memorized on the sirens or, (if  keeping it pressed during the power-on) to generate or modify this code. 
The receiving section is composed by a 

7 segments display, 3 signaling, 3 logical outputs and the button P2. 

The 

display allow to show from 1 to 8, which siren is signalizing a problem. 
The 

3 led

 allow to visualize the kind of anomaly detected on the sirens: 

tamper alarm DL1, missing supervision DL2 

and low battery level DL3.

  

The tamper led is reset with the main activation while the other two are reset when battery or radio signal are restored. If 
anomaly is detected on more than one siren, the display starts to cycle, displaying for 2 seconds the number of siren, 
while the 3 led show the type of anomaly noticed. 
Button P2 is used to access programming, memorize siren codes and exit programming. 
The sequence is the following: 
 
 

See the manual of wireless siren to learn about ATX2/S programming:

 

 
 

Description of outputs, inputs and buttons 
 
Input ON/OFF 

 

Terminal no. 3 and no. 4  

 
Terminal  no.3

  input to be connected to the ON/OFF output of the control panel. When going to LOW level (GND) for 

more than a second, there is a system ON transmission for 2 seconds. This is indicated with the letter “A” on a display, 
four flashes of the siren’s beacon and 1 LED blinking during the whole period of the low condition. When it returns to 
HIGH level for more than a second, there is a 2 second system OFF transmission, and the siren’s beacon lights up for 
about 10 seconds. 
 

Terminal no. 4 

input to be connected to the ON/OFF output of the control panel. When going to HIGH level (12 VDC) 

for  more  than  a  second,  there  is  a  system  on  transmission  for  2  seconds.  This  is  indicated  with  the  letter  “A”  on  a 
display,  four  flashes  of  the  siren’s  beacon  and  LED  1 blinking during the whole period of the high condition. When it 
returns  to  LOW  level  for  more  than a second, there is a 2 second system OFF transmission, and the siren’s beacon 
lights up for about 10 seconds 

 
 ALARM Input    

Terminal no. 5 and no. 6  

 
Terminal no. 5 

input to be connected to the alarm output of the control panel. When going to LOW level (GND) for more 

than a second, there is an alarm transmission to the siren for 2 seconds. Immediately after this, a modulated output gets 
activated and the piezoelectric indoor siren will sound too. Sound modulation goes from 2600 and 3600 Hz. 
Siren remains activated until alarm input returns to HIGH level. When it returns to HIGH level, after a

 

second, the piezo-

electric siren stop to sound and there is a 2 second transmission that keeps the radio sirens. 
 

Terminal no. 6

 input to be connected to the alarm output of the control panel. When going to HIGH level (12 VDC) for 

more than a second, there is an alarm transmission to the siren for 2 seconds. . Immediately after this, a modulated 
output gets activated and the piezoelectric indoor siren will sound too. Sound modulation goes from 2600 and 3600 Hz. 
Siren remains activated until alarm input returns to LOW level. When it returns to LOW level, after a

 

second, the piezo-

electric siren stop to sound and there is a 2 second transmission that keeps the radio sirens silent. 
 

 TAMPER Output  

Terminal

 

no. 7 and no. 8

 

 
This relay output (with normal closed contact) collects all tamper indications from the memorized sirens. When a tamper 
transmission is received from one of the sirens, the output opens for 2 seconds. The display and the 

tamper LED DL1

 

memorize and display the event. This condition persists until the next arming of the control panel. 

 
Supervision 

 

Terminal no. 9 

 

This open collector output collects lack of supervision signals from all memorized sirens. If no supervision signal is 
received from the memorized sirens in 3 hours, this output is switched to low level. The display and the 

supervision 

LED DL2 

display and memorize the event. This condition persists until the resolution of the problem causing the event.  

 
 