background image

 

10 

 

 

Description 

Explanation 

 

Zone indicators

 

These show which zone is under control.

 

Flame power 
 

Flame power of the zones, 

  is the lowest and 

 

  is the highest.   
 

 
 
The hotplates are fitted with mains powered electronic spark ignitors, so must be connected to mains power 
supply (i.e. nominal 220~240 V ac) to operate. If power is not available, the hotplate will still work but the burners 
will have to be lit with a match or similar.   

Depressing the gas control knob of any burner will activate the spark ignition for all burners. To light the burner, 
turn the gas control knob to the High Flame setting of the burner to be lit, while at the same time depressing the 
gas control knob to activate the spark ignition.   

Once the burner is alight continue to depress the gas control knob for 5 – 10 seconds to allow the flame 
safeguard to activate. If when you release the gas control knob, the burner flame goes out the flame safeguard 
has not heated up enough so repeat the ignition procedure after waiting 1 minute for gas to disperse. If problems 
with burner lighting persist, refer to the TROUBLESHOOTING section of these instructions.   

If power is not available, light a match or similar, then turn the gas control knob for the burner to be lit, to the 
High Flame setting. Once again if problems with burner lighting persist, refer to the TROUBLESHOOTING 
section of these instructions.   

When burner lights, adjust desired flame height. On finishing, turn control knob to off position marked with a 
black DOT.   

BURNER AND UTENSIL CHOICE   

 
The 

maximum

 utensil (pan) diameters in millimeters 

(mm) for each burner are:   
1. For Natural Gas hotplates   
 

Auxiliary (small) and Semi-Rapid (medium) = 

195 mm   
 

Rapid (large) = 230 mm   

 

Triple ring (wok) = 270 mm   

 
2. For Universal LPG hotplates   
 

Auxiliary (small), Semi-Rapid (medium) and 

Rapid (large) = 195 mm   
 

Triple ring (wok) = 230 mm   

 

 

The 

minimum

 utensil (pan) diameters in millimeters 

(mm) for each burner are:   
 

Auxiliary (small) = 80 mm   

 

and Semi-Rapid (medium) = 140 mm   

 

Rapid (large) and Triple ring (wok) = 195 mm   

 
For best efficiency and to ensure utensil handle does 
not overheat, place the utensil centrally on the burner 
and adjust the flame height so all the flame remains 
under the utensil.   
 

 

 

Содержание VGF60

Страница 1: ...venini com au user manual 2 year warranty VGF60 60cm gas cooktop...

Страница 2: ......

Страница 3: ...best potential or tips on cleaning please feel free to call us on the above number It is important that you read through the following instruction manual thoroughly to become familiar with the instal...

Страница 4: ...ooktop Installation and User manual Content Safety instructions 3 Product description 4 Installation 6 Start using your appliance 9 Maintenance and troubleshooting 11 Warranty 14 GHS604A G2CI GHS604B...

Страница 5: ...l sensory or mental capabilities or their inexperience or ignorance are not able to use the device safely should not use this device without supervision or instruction by a responsible person This app...

Страница 6: ...er connecting to gas check for leaks using soapy solution never a naked flame Where a flexible hose assembly is used ensure it is approved to AS NZS 1869 Class B 10mm diameter and no more than 1 0metr...

Страница 7: ...2 GHS604B G2CI 1R 2SR 1A With 2 types for option Front LPG 27 5MJ h NG 26 0MJ h 3 GH614AS G2CI 1W 2SR 1A With 2 types for option Right LPG 30 5MJ h NG 29 5MJ h 4 GH614BS G2CI 1R 2SR 1A With 2 types fo...

Страница 8: ...lip 4 sets Screws ST4 2x24 4 pcs LPG Injectors 4 pcs Elbow Washers 1 Elbow 3 washers Natural gas regulator 1 Technical Specifications Model Product Dimensions h x w x d mm Cut out Size w x d mm App x...

Страница 9: ...mm Horizontal surfaces adjacent the hob less than or equal to the hob height Ensure there is sufficient clearance to fit the regulator and or flexible hose connection with the hotplate in the install...

Страница 10: ...ame for correct operation If burner is placed correctly it will not rotate on its supports The Triple Ring Wok burner diagrams below does not fit over the igniter or thermocouple but must be placed on...

Страница 11: ...st be restrained from accidental contact with the flue outlet of an under bench oven This hose assembly shall be suitable for connection to a fixed consumer piping outlet located as follows Hotplates...

Страница 12: ...rer or agent as required ADJUSTED FOR NATURAL GAS 1 0kPa ADJUSTED FOR ULPG 2 75KPa NOZZLES DIAMETER mm Gas consumption MJ h NOZZLES DIAMETER mm Gas consumption MJ h WOK 1 70 13 0 WOK 0 98 13 0 Rapid 1...

Страница 13: ...er waiting 1 minute for gas to disperse If problems with burner lighting persist refer to the TROUBLESHOOTING section of these instructions If power is not available light a match or similar then turn...

Страница 14: ...Note S Ignition pin T Thermocouple Use a cotton bud tooth brush or some other item to clean out any incrustations or dirt from the four holes marked H The spark gas is 4 6mm Replace burners and ensure...

Страница 15: ...circuit breaker Loose sparker cable Call authorised representative Burner not aligned properly Remove and re fit burner Burner not lighting when spark ignition working Gas supply off Check gas supply...

Страница 16: ...Distributed by Home Appliances Pty Ltd 20 Carlotta Street Artarmon NSW 2064 Tel 02 9958 3111 Fax 02 9958 3555 Email info hapl com au Website www hapl com au...

Отзывы: