TROUBLESHOOTING 

Servicing of the hotplates must only be done by an authorised service representative (see back of this booklet) and the 

hotplate must not be modified. Power must be disconnected before any servicing or maintenance is conducted.   

DO NOT MODIFY THIS APPLIANCE. 

It is recommended the hotplate serviced by an authorized person at least every 2 years. This service is not covered by 

warranty. 

Abnormal conditions include: 

Excessively yellow or sooting flame type. 

Flame lifting off the burner ports. 

Flame lighting back into the burner (normally associated with a popping sound). 

Objectionable odour of the flames combustion products.

 

Should a faulty condition develop in the hotplate that is not described above, refer to the following table first for possible 

causes and remedies prior to contacting an authorised  service representative. Servicing beyond the remedies  listed 

shall only be undertaken by an authorised service representative.   

FAULT 

POSSIBLE CAUSE 

REMEDY 

No spark when gas control 

knob depressed.   

No power. 

Check plugged in and switched on. 

Check mains circuit breaker.   

Loose sparker cable. 

Call authorised representative. 

Burner not aligned properly. 

Remove and re-fit burner. 

Burner  not  lighting  when 

spark ignition working.   

Gas supply off. 

Check gas supply valve on. 

Burner not aligned properly. 

Remove and re-fit burner. 

Burner ports blocked. 

Remove, clean and replace burner. 

Burner  goes  out  when 

control knob released.   

Flame safeguard not activated. 

Re-light, allow more time for flame safeguard 

to activate.   

Flame  safeguard  faulty  connection  or 

broken.   

Call authorised representative. 

Uneven  flame  pattern  or 

slight flame lifting.   

Burner ports blocked. 

Remove, clean and replace burner. 

At  minimum  flame  setting 

the flame is too high.   

Turndown control setting incorrect. 

Call authorised representative. 

Small  flame  on  High 

setting.   

Regulator faulty. 

Call authorised representative. 

Gas supply pressure low. 

Call authorised representative. 

Incorrect injector fitted. 

Call authorised representative. 

Blocked injector or gas supply tube. 

Call authorised representative. 

Incorrect utensil size. 

Refer to operating instructions utensil choice. 

Flame  too  high  on  High 

setting.   

Regulator faulty. 

Call authorised representative. 

Incorrect injector fitted. 

Call authorised representative. 

Incorrect utensil size. 

Refer to operating instructions utensil choice. 

Содержание VCG64

Страница 1: ...venini com au user manual 2 year warranty VCG64 60cm Gas Cooktop...

Страница 2: ...l sensory or mental capabilities or their inexperience or ignorance are not able to use the device safely should not use this device without supervision or instruction by a responsible person This app...

Страница 3: ...er connecting to gas check for leaks using soapy solution never a naked flame Where a flexible hose assembly is used ensure it is approved to AS NZS 1869 Class B 10mm diameter and no more than 1 0metr...

Страница 4: ...HS604B G2CI GFC60 VGF60 1R 2SR 1A With 2 types for option Front LPG 27 5MJ h NG 26 0MJ h 3 GH614AS G2CI 1W 2SR 1A With 2 types for option Right LPG 30 5MJ h NG 29 5MJ h 4 GH614BS G2CI 1R 2SR 1A With 2...

Страница 5: ...s Screws ST4 2x24 4 pcs LPG Injectors 4 pcs Elbow Washers 1 Elbow 3 washers Natural gas regulator 1 Technical Specifications Model Product Dimensions h x w x d mm Cut out Size w x d mm App x net weigh...

Страница 6: ...mm Horizontal surfaces adjacent the hob less than or equal to the hob height Ensure there is sufficient clearance to fit the regulator and or flexible hose connection with the hotplate in the install...

Страница 7: ...ame for correct operation If burner is placed correctly it will not rotate on its supports The Triple Ring Wok burner diagrams below does not fit over the igniter or thermocouple but must be placed on...

Страница 8: ...st be restrained from accidental contact with the flue outlet of an under bench oven This hose assembly shall be suitable for connection to a fixed consumer piping outlet located as follows Hotplates...

Страница 9: ...1 0kPa ADJUSTED FOR ULPG 2 75KPa NOZZLES DIAMETER mm Gas consumption MJ h NOZZLES DIAMETER mm Gas consumption MJ h WOK 1 70 13 0 WOK 0 98 13 0 Rapid 1 40 9 5 Rapid 0 90 10 0 SEMI RAPID 1 10 6 0 SEMI...

Страница 10: ...rsist refer to the TROUBLESHOOTING section of these instructions If power is not available light a match or similar then turn the gas control knob for the burner to be lit to the High Flame setting On...

Страница 11: ...Note S Ignition pin T Thermocouple Use a cotton bud tooth brush or some other item to clean out any incrustations or dirt from the four holes marked H The spark gas is 4 6mm Replace burners and ensure...

Страница 12: ...circuit breaker Loose sparker cable Call authorised representative Burner not aligned properly Remove and re fit burner Burner not lighting when spark ignition working Gas supply off Check gas supply...

Страница 13: ...venini com au...

Отзывы: