INSTALLATION INSTRUCTIONS
GAS FLOW ADJUSTMENT
In order to adjust the minimum gas flow proceed as follows:
x
Ignite the burner and turn down to the minimum setting.
x
Remove the control knob from the gas tap.
x
Adjust the flow either clockwise to decrease or anti-clockwise to increase the flame. Use a
screwdriver inserted down the gas tap rod or via the screw head adjacent to the rod for
models fitted with a Flame Supervision Device.
x
Check that the flame is 3- 4 mm in length, bluish in colour, stable and noiseless, and does not
extinguish when changing from maximum to minimum flow.
x
Replace the control knob and check that all components have been reassembled correctly.
Before Leaving
-
Check all connections for gas leaks with soap and water.
DO NOT
use a naked
flame for detecting leaks. Ignite all burners to ensure correct operation of gas valves, burners and
ignition. Turn gas taps to low flame position and observe stability of the flame. When satisfied
with the hotplate, please instruct the user on the correct method of operation. In case the
appliance fails to operate correctly after all checks have been carried out, refer to the authorised
service provider in your area.
11
Содержание V3G1WC6
Страница 1: ...GAS HOBS USER AND INSTALLATION INSTRUCTIONS...
Страница 16: ...15...