Electrical requirements and installation requirements
Power Requirements
IMPORTANT
Observe all governing codes and ordinances. The customer is responsible for: Contacting an electrician-installer. Check that the
electrical installation is adequate and in conformance with the National Electrical Code, ANSI / NFPA 70 (latest edition *) or CSA
Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 (the latest edition **) of the CSA, and all codes and
ordinances in your area. If codes permit and use a wire to separate the ground, it is recommended to check the path of the wire
by an electrician. Do not put the device to land on a gas line. Consult a qualified person if you are not sure that the hood is
properly grounded electrically. Do not install a fuse in the neutral circuit or circuit ground.
Location of the electrical installation
• The cable must enter the rear wall at least 20 to 1/4 "above the height of the installation base, and between 7-5/8" and 4-7/8
"from the left side of the midline.
MPORTANT
Keep these instructions in order to return them to the electrical inspector. The hood must be plugged directly into a 110 volt wall
outlet.
Before installing the hood
1. To ensure the most efficient ventilation possible, install the pipe in a straight line or with the least elbows possible.
CAUTION: The output of the vent pipe should give to the outside.
2. Two people are required for installation.
3. Supplied hardware can secure the hood to most walls and ceilings, consult a qualified installer to ensure that the hardware provided is suitable for your type of
wall or cabinet.
4. In the case of areas prone to COLD WEATHER, install a check against extra-circulation to minimize the cold air return and a nonmetallic thermal break to
minimize conduction of outside temperature in the duct. The valve must be placed on the side of the cold air from the heat insulator.
The insulation must be placed as close as possible to where the pipe enters the heated part of the house.
5. Air booster: The building code in your area may require the use of a make-up air system if you use a ventilation system which leads the movement of air
exceeding a certain number of CFM. The number of ft3/min varies from one region to another. Consult your HVAC professional for specific requirements in your
area.
Remove the packaging.
CAUTION
Carefully remove the cardboard, gloves to protect against sharp edges.
Содержание VT-ANG30
Страница 8: ...Exit 4 1 2 x 9 include Exit 3 1 4 x 10 include ...
Страница 12: ...Insert Hood models VT IN2816 VT IN2812 Positioning options for blocks ducts hoods maximum length pipe is 20 ...
Страница 16: ...Installation and dimensions diagram patterns for hood s chimney ...
Страница 17: ...17 Installation and dimensions diagram patterns for island hoods VT ANG36il VT VIT36il ...
Страница 19: ...19 Installation and dimensions diagram patterns for island hoods ...
Страница 20: ...Installation and dimensions diagram patterns for hoods VT PROC30 VT PROC36 ...
Страница 21: ...21 Installation and dimensions diagram patterns for hoods VT PROC30 VT PROC36 ...
Страница 23: ...23 Horizontal installation dimensions diagrams for models of hoods VT REG30 VT REG30W VT CON30 ...
Страница 24: ...Vertical installation dimensions and patterns diagram for hoods VT REG30 VT REG30W VT CON30 ...
Страница 25: ...25 Vertical installation dimensions and patterns diagram for hoods VT IN2816 ...
Страница 26: ...Vertical installation dimensions and patterns diagram for hoods VT IN2812 ...