V21 Parts & Service Manual
All V21 Identified Equipment
REV A – 10/2013
P/N: 1230255
V21
12.4 Programming HV3 / CHAMELEON | P1-4
Test Mode Display:
Allows you to verify that all of the characters on the display illuminate.
1.
At “Test Mode” press Button 4.
2.
Press Button 2 or 3 to scroll until display reads “Test Mode - Display.”
3.
Press Button 4.
4.
All of the characters on the display should illuminate.
5.
Press Button 4 to exit.
Selection Switch Testing:
Allows you to test the selection switches.
1.
At “Test Mode” press Button 4.
2.
Press Button 2 or 3 to scroll to “Test Mode Switches”.
3.
Press Button 4
4.
Press desired selection switch to be tested.
5.
To exit press Button 1 and hold for 3 seconds.
Test Mode Relays:
Allows you to test the compressor, evaporator fan, lights and heater.
1.
When “Test Mode” is displayed press Button 4.
2.
Press Button 2 or 3 to scroll until display reads “Test Mode - Relays”
3.
Press Button 4.
4.
Press Button 2 or 3 to advance through sub-modes.
5.
Press Button 4 at “Compressor” prompt to test compressor.
6.
Press Button 4 at “Light” prompt to test lighting system.
7.
Press Button 4 at “Fan” prompt to test evaporator fan.
8.
Press Button 4 at “Heater” prompt to test optional heater.
9.
Press Button 1 to exit sub-modes.
Cash Data:
This Mode allows you to retrieve historical information regarding the money accepted by the
vendor. To clear the individual selection cash data, you must have the MIS Auto Reset in the
“Configuration” mode turned to ON.
1.
When “Cash Data” is displayed press Button 4. The non-resettable historical data is
displayed.
2.
Press Button 2 or 3 to display resettable individual selections.
3.
To reset historical data, make sure the
MIS Auto Reset is turned ON in the configuration
mode.
4.
Press Button 1 to exit mode.