416298
H200
7-15-99A
9-29-00B
INST INSTRUCTIONS
VC 416/516
SUPERCEDES
TITLE
DATE
SECTION
III. Power Sources
B. Electric Double and Single Acting Pump Information
Note:
Pumps should be mounted in the horizontal position. Check hose lengths when choosing
a pump mounting location.
See Dwg. 416080 (Fenner Double-Acitng) or 416306 (Monarch Double-Acting).
1.
Position electric pump on truck frame, mark mounting holes on frame and drill through 7/16" dia.
holes (2 places). Mount pump to frame with 3/8"-16 x 1" hex head bolts (grade 5).
Warning
High pressure (3000 PSI) is developed by these pumps. Do not use hydraulic hoses that are
crimped, cut, abraded, worn or damaged in anyway. Replace hydraulic hose(s) if any damaged
condition exists. Use only hydraulic hose rated at a working pressure of 3000 PSI.
Use only steel fittings rated at a working pressure of 3000 PSI in the electric pump hydraulic
system. Replace the fittings if found damaged (bent, cracked, threads damaged, etc.). Do not
over tighten connections.
C. Double Acting Electric Pump Installation
1a. Attach one end of 7' hose to elbow at port "B" (rod end) of the hoist cylinder. Elbow fittings
are not required if 90° elbow ports are on the cylinder. Attach one end of the 5' hose to the
hoist cylinder at port "A" (full end). See Dwg. 416080 (Fenner Double-Acting) or 416306
(Monarch Double-Acting).
Note:
The Monarch double-acting power unit does not require an external flow control (it is built
into the power unit).
b. Attach free end of the 7' hose to the swivel elbow on the pump at port marked "B". Attach free
end of the 5' hose to the flow control valve (Fenner power unit only) on the pump at port marked
"A" - on the Monarch power unit the 5' hose attaches directly to the pump port.
2a. Locate and attach electric pump switch and switch mount on truck dash.
b. Attach proper color coded wiring from switch to solenoid and in-line fuse to center posts and hot
lead under dash as shown. See Dwg. 416080 (Fenner Double-Acting) or 416306 (Monarch
Double-Acting).
c. Attach positive lead (#4 gauge) from positive terminal of battery to other large post on motor
solenoid. See Dwg. 416080 (Fenner Double Acting) or 416306 (Monarch Double-Acting).
3.
Fill pump with commercial grade ATF-DEXRON II oil 1/2" from the top of the reservoir.
Содержание VC 416
Страница 1: ......
Страница 2: ......
Страница 7: ...TITLE SECTION SUPERCEDES DATE 416266 H100 2 28 90 7 14 98 CAPACITY CHART VC 416 MANUFACTURING INC...
Страница 8: ...TITLE SECTION SUPERCEDES DATE 516203 H100 2 28 90 7 14 98 CAPACITY CHART VC 516 MANUFACTURING INC...
Страница 9: ......
Страница 10: ...TITLE SECTION SUPERCEDES DATE 416289 H200 7 14 98 INST INSTRUCTIONS VC 416 516 MANUFACTURING INC...
Страница 12: ...416291 H200 7 14 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 13: ...416292 H200 7 14 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 15: ...416257 H200 2 14 01B 6 22 01C SUBFRAME MOUNTING VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 16: ......
Страница 17: ...416294 H200 7 14 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 18: ...416295 H200 7 15 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 19: ...416296 H200 7 15 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 20: ...416297 H200 7 15 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 21: ...TITLE SECTION SUPERCEDES DATE 520078 H200 3 15 90 7 13 98A PTO PUMP CABLE INST VC 520 6628 MANUFACTURING INC...
Страница 26: ...416299 H200 7 15 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 27: ......
Страница 29: ...416300 H200 7 15 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 30: ...416273 H200 9 16 92 7 15 98A INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 31: ...416301 H200 7 15 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 32: ...416302 H200 7 15 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 33: ...416303 H200 7 15 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 34: ...416304 H200 7 15 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 39: ...TITLE SECTION SUPERCEDES DATE 416508 8 27 98 REPL PARTS DWG 416081M POWER UNIT MANUFACTURING INC...
Страница 42: ......
Страница 43: ......
Страница 44: ......