English
- 78 -
TUO Wi-Fi RF Chronothermostat with humidistat User Manual
Configuring the connection with the remote actuators
To configure the remote actuator:
1. activate the "network configuration" mode on the remote actuator
(for the procedure, see the specification of the remote actuator). The actuator
remains in configuration mode for about 30 seconds, the time within which the
device TUO Wi-Fi RF must send the pairing code
2. choose the channel to configure (
OUT
,
DEU
or
FAN
) and go to the configuration
page of Tuo Wi-Fi RF device
3. press the key for at least 3 seconds until the symbol lights up:
the pairing code has been sent and the devices are paired.
3s
During normal operation, sending the commands to the actuators is indicated by the
lighting of the RF message.
It is possible to repeat the procedure described above to combine multiple remote
actuators to be used for simultaneous drives.
Resetting the device (page 80) modifies the pairing code used by the device
itself to communicate with the actuator. For this reason,
after a reset of the device,
it is necessary to reconfigure all the previously associated remote actuators.
Remote actuator test
To take the test:
1. press the key or to display
tst
.
2. press and hold the key until the symbol appears: the device sends a
sequence of on-off commands of 10 seconds each to the remote actuator.
Check during this phase the effective switching of the actuator relay
3. the test ends 15 minutes after activation or by pressing the key .
3s