Vemer Sensor-T Скачать руководство пользователя страница 2

ISCOM019-1603

Mod.

 Sensor-T

2

Sensor-2T

User manual

Movement detectors

Read all instructions carefully

 

The  

Sensor-T

 and 

Sensor-2T 

proximity switches are electronic switching devices 

containing micro-disconnection (μ) according to EN 60669-2-1. The output circuit is 

activated when a heat source moves in front of the device and is deactivated when no 

movement is intercepted, after an adjustable period of time. Sensor-2T also has a second 

output circuit that functions independently from the level of lighting.

 SAFETY WARNINGS

 

During product installation and operation it is necessary to observe the following 

instructions:

1)   The instrument must be installed by a qualified person, in strict compliance with 

the connection diagrams

2)   Do not power the instrument if any part of it is damaged

3)   The instrument must be installed and activated in compliance with current 

electric system standards

4)   The electrical system in the building in which the instrument is to be installed 

should have an over-current switch and a protection device

5)   The instrument can be used in environments with pollution degree 2

6)   Before accessing the connection terminals, verify that the leads are not live

7)   After installation, inaccessibility to the connection terminals without appropriate 

tools must be guaranteed.

Code Model 

Description

VE215000 Sensor-T 

Ceiling movement detector

VE216800 Sensor-2T 

Ceiling movement detector

 TECHNICAL CHARACTERISTICS

•  Power supply: 230V AC  50-60 Hz

•  Relay contacts capacity at 250 V AC: 10 A (resistive load)

• 

Sensor-T:

 

Load (L

#

-N) for lighting:

 

- Incandescent Light: 2200W

 

- Halogen Light 230V: 2200W

 

- Low Voltage Halogen Light: 2000VA

 

- Fluorescent Light: 1200VA

 

- Energy Saving Lamp (CFL): 1000VA

 

- LED Lamp: 500 VA

•  

Sensor-2T:

 

Load (L

#

-N) for lighting:

 

- Incandescent Light: 2200W

 

- Halogen Light 230V: 2200W

 

- Low Voltage Halogen Light: 2000VA

 

- Fluorescent Light: 1200VA

 

- Energy Saving Lamp (CFL): 1000VA

 

- LED Lamp: 500VA

•  Consumation:    − Sensor T: 7VA capacitive (ca. 1,1W) 

− Sensor 2T: 4.2VA inductives (ca. 3.1W)

•  Luminosity range: 10-1000 lux

•  Timing range: 

− Sensor-T: T1: from 1s to 10 minutes

 

 

− Sensor-2T:  T1: from 10s to 10 minutes,  

T2: from 10s to 15 minutes

•  Detection angle: 360°

•  Detection field: up to 7m in diameter to 2.5m in height

•  Operating temperature: -10 °C ÷ +45 °C

•  Type of protection: IP20

•  Degree of protection: Class II

 INSTALLATION

•  The device must be installed far away from inductive loads (motors, transformers, telephone 

aerials, transformation stations, industrial machinery, etc.) inasmuch as particularly strong 

magnetic fields could affect its operation. Do not mount on conductive surface. 

The device must also be protected against rain and the sun’s rays and should not be placed 

near lamps or heat sources. The device should not be secured to the ceiling in the vicinity of 

highly reflective surfaces or elements subject to sudden temperature changes or light sources.

•  Make a hole with a diameter of 65 mm in the material to support the device (the material 

must be between 5 and 25 mm thick). Open the cover on the supply module that covers the 

compartment of connection terminals, then connect the power supply and the load according 

to the wiring diagrams, close the cover after checking the connections made. Then open the 

cover which is located on the opposite side of the power supply module in order to connect the 

product simply by hooking the special connector. Then introduce the power supply module in 

the hole prepared for the insertion of the sensor. Secure the sensor using the springs, lifting it 

upwards and inserting it inside the hole, pushing the sensor in until the edge rests against the 

ceiling.

Dimensions

Connection diagrams

•  You should also bear in mind that detection takes place where the two axes cross over and 

therefore, if the heat source moves in parallel to the axes, the detection will take place at a 

shorter distance.

GREATER SENSITIVITY

LESS SENSITIVITY

•  If two Sensor-T/2T are connected in the same room, the lamp of one should not be positioned 

in the detection field of the other.

 OPERATION

•  A screwdriver can be used to adjust the various parameters via the trimmer (3 for the 

Sensor-T, 4 for the Sensor-2T).

•  To adjust the detection field, turn the “LUX” knob to the position “

” and the “T1” knob to the 

minimum position (in the case of Sensor-2T, turn also the knob “T2”). Now move inside the 

limits of the detection field and take action on the potentiometer “SENS” if necessary in order 

to adjust the coverage area. The sensor can move into six positions, guaranteeing an angle of 

up to 30°. It can rotate by 350°. The device comes with an accessory that makes it possible 

to limit the device’s field of action. This accessory is divided into twelve sectors, with two 

different heights. Each sector makes it possible to block an area of 30°. The sensors have a 

red light inside them that turns on once the detection occurred. Then you can use this LED as 

an aid for adjusting the detection field without the need to connect a load.

•  The luminosity can be adjusted using the “LUX” knob, which makes it possible to set the 

device so as to guarantee interventions only in conditions of luminosity below the set level. 

 

By turning the knob to position “

” the output circuit is activated in any condition of 

luminosity, while in position “

” it is only activated in conditions of low luminosity. 

 

The second output circuit of  Sensor-2T operates independently from the set level.

•  The “T1” knob makes it possible to set the period of time in which to keep the load activated 

following the detection of movement. The timer range starts from a minimum of 1 second to a 

maximum of 10 minutes. 

 

The Sensor-2T has a second output circuit that activates in case movement is intercepted 

within the coverage area and that works with any condition of luminosity.

 

The de-excitation time available only on Sensor-2T, may be within the range of 10 seconds 

and 15 minutes with the knob “T2”.

•  In the Sensor T there is the possibility to manual activate the load for the time T1 closing the 

clean contact (between N and P). In this way the load will turn on without the sensor has 

detected something and with any condition of luminosity.

•  Turn off power when change the light sources.

 REFERENCE STANDARDS

Conformity to the EU directives:

2006/95/EC (low voltage)

2004/108/CE (EMC)

is declared with reference to harmonized standard:

EN 60669-2-1

direction of 

movement

GREATER SENSITIVITY

direction of 

movement

LESS SENSITIVITY

28-MLORB465/A-VE

121

38

59.5

5 - 25 mm

Ø65
Ø80

Ø63

Sensor-T

Sensor

Power supplier

N

L

T

2

N

T

1

L

C1

C2

B

A

N

L

N

L

N

L

A

N

L

N

P

Sensor-2T

Description

1'

2'

3'

5'

10'

30''

2'

3'

5'

10'

15'

10''

30''

1'

10''

T2

S

T1

LUX

SENS

SPRING 

FIXING

QUICK 

CONNECTOR

SUPPLY 

MODULE

CEILING 5-25 MM