REFERENCE STANDARS
Compliance with Community Directives:
2014/35/UE (Low voltage) 2014/30/UE (EMCD) 2014/53/UE (RED)
is declared in reference to the harmonized standars:
• EN 60950-1
• EN 301 489-3, EN 301 489-1, EN 300 220-1, EN 300 220-2
1
2
3
4
5
230V
COM
~
NO
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: [email protected] - web site: www.vemer.it
V3IS00805-010-032017
Mod.
RX.16A
3
4
5
1
User Manual
REMOTE ACTUATOR RX.16A
Read all instructions carefully
DIMENSIONS
WIRING DIAGRAMS
INSTALLATION
OPERATION
2
The remote actuator RX.16A is an automatic control device with
independent installation designed to receive radiofrequency signals coming
from Vemer radiofrequency devices.
It performs actions of type 1B and it is intended for operating in rooms
or similar with pollution overload category III and degree of pollution 2
(EN60730-1).
Code
Model
Description
VE736500
RX.16A
Flush mounting remote actuator
SAFETY WARNINGS
During the product installation and opeartion it is necessary to observe the
following instructions:
1) The product must be installed by a qualified person;
2) Do not power the product during installation;
3) Do not power or connect the product if any parts appears to be damaged.
4) The product must be installed in compliance with the wiring diagrams of this
manual and on the product.
5) After installation, inaccessibility to the connection terminals without
appropriate tools must be guaranteed.
6) The instruments must be installed and activated in compliance with current
electric system standards.
7) In the electrical system of the building where the instrument must be
installed, a switch and a protection device from the overcurrents must be
present.
TECHNICAL SPECIFICATIONS
• Power supply: 230Vac (-15% ÷ +10%) 50/60 Hz
• Output: bistable relay with interruption power of 16(8)A / 250Vac
• Max distance from transmitter: 30 meters in inside homes
• Operating antenna frequency: 433.92 MHz
• Operating temperature: 0 ÷ 40°C
• Storage temperature: -10°C ÷ +70°C
• Enclosure: suitable for the flush mounting box (one module dimension)
• Degree of protection: IP20
• Type of action: 1B
• After switching on the red LED flashes twice for half a second (switching-on
sequence).
• Once lighting sequence is over, the green LED lights to inform about normal
operation and the red led lights to give the corresponding state of the
channel (switched on = ON).
• The command device (transmitter) requires the combined relay actuation
(relay ON/OFF) only after the channel configuration.
• When radio link interruption between transmitter and receiver is over 15
min, the relay is disabled and the red LED flashes. Reset is automatic.
Channel configuration
° During normal operation, hold down the key for almost three seconds to
enter configuration mode. Green LED is off while red LED flashes.
° The product holds configuration mode for max 60 seconds, within this
period the actuator must receive a configuration string from the command
device. (see instructions for string input mode).
° When string is received, the channel is configured and the actuator restarts
its normal operation.
° To reconfigure the channel, repeat the procedure.
• To reset the channel configuration, enter the configuration mode (holding
down the key for almost 3 seconds until the red LED restarts flashing), then
hold down the key for almost three seconds until the green LED lights.
Every new configuration resets the previous one.
20
42
35
INDICATIONS AND CONTROLS
1
– Channel configuration key
2
– Bicolor red/green operating state indicator
1