background image

E

n

g

li

s

h

- 28 -

User manual memo DW E

±

   confirm with 

“Ok”

 

−  choose MODIFY and press 

“Ok”

 to insert the new pin code. Use 

keys 

“C1”

 and 

“C2”

 to enter the digits composing the code one 

by one and 

“Ok”

 to confirm them

 

−  choose RESET should you wish to deactivate the pin code request

±

   press 

“Ok”

 to confirm

±

   on the display appear the words

 (

 in the case of 

reset)

If the pin code request is active, about 3 
minutes after the last time the keypad is 
pressed, keypad lock is activated. At this 
point pressing on the keypad again leads 
to a request to enter the pin code.

To unlock the instrument simply enter the 
pin code according to this rule:

-  key 

“   ”

: 1   

 

key 

“C1”

: 2  

 

key 

“C2”

: 3  

 

key 

“Ok”

: 4

For example: 

pin: 3411 

“C2”

 

“Ok”

 

“   ”

 

“   ”

RESET SETTINGS Menu

This option resets all settings relative to:
-  date format
-  automatic change DST/CET
-   minimum and maximum time between two casual switchings
-  programme options
-  pin code

To reset the settings:

±

   choose SETTINGS RESET using keys 

“C1”

 and 

“C2”

 

±

   confirm with 

“Ok”

 . 

±

   confirm again with 

“Ok”

 

±

   on the display appear the words 

The factory values are reloaded thus:

Date format 

dd--mm--yy

Change DST/CET
- change summer time
- change winter time

automatic
Last Sunday of March at 02:00
Last Sunday of October 03:00

Casual programme
- minimum period
- maximum period

1 minute
5 minutes

Request PIN

0000 - disactivated

Содержание Memo DW E

Страница 1: ...10 Lock output switchings Lock page 10 Battery test page 11 Menu Overview page 12 Automatic programming page 13 Creation of a new programme page 13 Programmes ON OFF page 13 IMPULSE Programmes page 1...

Страница 2: ...able switches Large display with text guide to facilitate programming Sealable cover and possibility to lock keypad through password Time switch with daily weekly programming for the management of ele...

Страница 3: ...nt must be installed and activated in compliance with current electric systems standards 6 Do not use the instrument for anything other than the indicated purpose Code Model Description VP871800 memo...

Страница 4: ...English 4 User manual memo DW E DIMENSIONS CONNECTION DIAGRAMS...

Страница 5: ...ock lock relay switchings f Field random programme g Field day of the week h Field programme running i Field CET DST j Field key functions Key activation menu esc check battery Key Ok confirm datum Ke...

Страница 6: ...segments of the display will light for a few seconds and then the instrument shows the version of the firmware and the type of instrument At this point it is possible to insert the parameters necessar...

Страница 7: ...s Use keys C1 and C2 to choose the desired value and press Ok to confirm and go on to the next parameter The sequence of parameters to be entered is year month day When the day is inserted also appear...

Страница 8: ...and OFF events consist of switching the relay to the on or off position They may be daily every day at the same time or weekly one or more days during the week each week IMPULSE events An impulse even...

Страница 9: ...rent events starting at the same moment the instrument will only run the one with the highest priority according to the following table 1 maximum priority Event Weekly Daily Cycle 1 Impulse 2 3 ON or...

Страница 10: ...les the default minimum period is 1 minute and the maximum 5 minutes such values can in any case be changed in the settings menu Hold keys C1 and Ok down simultaneously for 3 seconds to activate the f...

Страница 11: ...once a week Monday at 00 00 It is in any case possible to read battery status by holding down key for 3 seconds On the display appear the words if the battery charge level is sufficient for correct o...

Страница 12: ...English 12 User manual memo DW E Menu Overview...

Страница 13: ...menu choose the PROGRAM option using keys C1 and C2 and press Ok to confirm Choose option NEW using keys C1 and C2 and press Ok to confirm Using keys C1 and C2 choose the frequency of the event from D...

Страница 14: ...ument activates the recursive function which allows several on off events to be programmed in succession on the same day Thereby once an activation deactivation event has been programmed it is possibl...

Страница 15: ...Ok to confirm Choose the impulse using keys C1 and C2 and press Ok to confirm Using keys C1 and C2 choose whether it is an ON impulse or an OFF impulse Press Ok to confirm Se the date using keys C1 a...

Страница 16: ...the words During normal operation the eventual execution of an impulse programme is shown by symbol on field 8 of the display 1 3 CYCLE Programmes Press key to enter the menu choose the PROGRAM optio...

Страница 17: ...calculated so that the last period is always complete The maximum duration of a cycle is one week Press Ok to confirm Once programming is confirmed on the display appear the words During normal opera...

Страница 18: ...the details of the interval are to be considered as included in the period As confirmation of programming on the display appear the words During normal operation the eventual execution of a holiday p...

Страница 19: ...amme in the memory in order to enter a new one The message is shown on the display whenever there is an attempt to save a programme overwriting a pre existent programme of the same type for example tr...

Страница 20: ...o insert the new programme parameters The parameter under modification flashes Use keys C1 and C2 to set the values and Ok to confirm or the key to exit without modifications At the end of the modific...

Страница 21: ...e options modify delete and next to go to the next programme cycle At this point using keys C1 and C2 choose the desired option and press Ok to confirm 3 Reset programmes To delete all the programmes...

Страница 22: ...ormal operational status press key choose SETTINGS using keys C1 and C2 press Ok to confirm LANGUAGE Menu choose SETTINGS LANGUAGE using keys C1 and C2 confirm with Ok the currently set language is di...

Страница 23: ...display appear the words TIME Menu choose SETTINGS TIME using keys C1 and C2 confirm with Ok the current time displayed press Ok to access the modification enter hours and minutes using keys C1 and C2...

Страница 24: ...ays to be set To set the days and the time in which CET DST time change occurs choose SETTINGS DAYL SAVE using keys C1 and C2 confirm with Ok The words AUTO ON appear on the display should this not ha...

Страница 25: ...sen date the day of the month is requested in the other cases you are asked to enter the day of the week on which the time change is to happen Press Ok to confirm enter the time of the change Press Ok...

Страница 26: ...the minimum and maximum time which passes between two switchings when a casual programme is activated As default these values are set at 1 and 5 minutes choose SETTINGS RANDOM using keys C1 and C2 con...

Страница 27: ...roll the various types of programmings using keys C1 and C2 and press key Ok to access modification of the selected parameter once in modify choose keys C1 and C2 if you want to enable or disable the...

Страница 28: ...de To unlock the instrument simply enter the pin code according to this rule key 1 key C1 2 key C2 3 key Ok 4 For example pin 3411 C2 Ok RESET SETTINGS Menu This option resets all settings relative to...

Страница 29: ...ble to restore the initial status of the instrument using the reset function 4 different resets are available reset settings cancel all the entered settings reset programmes cancel all the saved progr...

Страница 30: ...unt the cover turning it clockwise connect the power supply In order not to lose programming and the performed settings it is necessary to make sure that no more than 60 seconds pass between extractin...

Страница 31: ...sofinactivityofthekeyboard Code Model Description Powersupply VE462800 MemoDWE Timeswitchdaily weekly1relay 12Vac dc VE463600 MemoDWE Timeswitchdaily weekly1relay 24Vac dc TECHNICALINFORMATION GENERAL...

Отзывы: