INSTALLATION KIROS-INT (code VE780001)
• Install the chronothermostat at a height of about 1.5 m from the floor, away
from direct radiation, away from doors, windows, heat sources, locations
with excess or total lack of ventilation.
• The device can be adapted to the cover plates of Berker, Busch-Jaeger, Gira, Jung
and Merten, using one of the two assembly sequences illustrated below.
The complete list of compatible cover plates is available on the website
www.vemer.it on the product page.
Cover plate
(not supplied)
Intermediate panel
(not supplied)
DEVICE
WITH METALLIC FRAME
Flush-mounting box
COVER
(WHITE / GREY)
DEVICE
CLOSING FRAME
(WHITE / GREY)
DEVICE
WITH METALLIC FRAME
Cover plate
(not supplied)
Intermediate panel
(not supplied)
DEVICE CLOSING FRAME
(WHITE / GREY)
Flush-mounting box
a
Connect the load and power supply (see connection diagram)
b
Fasten the device with the metal frame to the flush mounting box and mount
the cover of the device (colour white / grey)
c
Apply the cover plate and the 50x50mm intermediate panel
d
Finally insert the closing frame (colour white / grey)
Assembly sequence 1
a
Connect the load and power supply (see connection diagram)
b
Fasten the device with the metal frame to the flush-mounting box
c
Apply the cover plate and the 50x50mm intermediate panel
d
Finally insert the closing frame
Assembly sequence 2