ASCII Command Set List
The VR2C ASCII command list can be categorized according to each command’s purpose as presented in
the following table.
Purpose
Command
High Level Description
Serial Communication
Port Control
BAUDRATE=x
Sets the serial port baud rate.
QUIT
Disables serial transceivers.
Basic Receiver
Control/Status
INFO
Retrieves VR2C information
STATUS
Retrieves VR2C current status
START
Enter ‘Record’ mode
STOP
Enter ‘Pause’ mode
TIME=x
Sets the VR2C’s clock.
ERASE
Erases the VR2C’s tag detection memory
STORAGE
Enter ‘Suspend’ mode
RESETBATTERY
Resets VR2C battery usage indicator
Real-Time Mode Control
RTMPROFILE=x
Set RTM Profile
RTM232
Starts RTM using RS232 lines
RTM485
Starts RTM using RS485 lines
RTMNOW
Resets RTM output schedule (Polling mode)
RTMINFO
Retrieve RTM configuration
RTMOFF
Disable RTM output
RTMAUTOERASE=x
Set RTM auto erase threshold
Detection Log Manual
Retrieval (Advanced User
Feature)
READBEG
Set read pointer to the beginning of data
READEND
Set read pointer to the end of data
READREC
Read detection log record at read pointer address
READACK
Increment read pointer to next detection log record
3.2.3
Enabling/Disabling Receiver Serial Transceivers
To conserve power, the VR2C disables its serial RS232/RS485 transceivers after either 30 seconds of
inactivity on the communication lines or issuance of the ASCII
QUIT
command. Once disabled, the serial
transceivers need to be enabled again prior to sending any additional serial commands to the VR2C. The
transceivers can be enabled by sending the receiver any ASCII character followed by a short delay of at least
100ms.