To operate the macerator, open the OVERBOARD THRU-HULL for the appropriate tank (fwd or 
aft).  The aft THRU-HULL is located under an access panel in the galley floor. The fwd Thru-HULL 
is located under the fwd bed. Then turn on the MACERATOR circuit breaker on the DC electrical 
panel.  Listen to the macerator’s sound.  When the pitch becomes higher, the tank is empty.  
Discharge may be observed on the fwd starboard side, or aft port side. It should only take a few 
minutes to empty the tank.

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Y-Valve

 

 

The Y-VALVE directs waste effluent into the sanitation-holding tank or flushes the effluent ‘directly 
overboard’.  The Y-VALVE is located adjacent to the aft THRU-HULL.  A plastic strap keeps the 
handle pointed to the holding tank – the normal position. 
 
Note -- Y-valves are usually wire-tied to the holding tank position in respect to Coast Guard 
regulations.  Please leave it “as is” unless there is an emergency.  Be familiar with the applicable 
laws concerning dumping sewage directly overboard.

 

 

 

WATER SYSTEMS 

 

Fresh Water Tank(s) 

 

The FRESH WATER tanks hold 165 gallons in 2 tanks. Observe the 
water level by the indicator gauge.  Be mindful of the amount of water 
you use while washing dishes and taking showers. Waste water from 
the sinks and showers drains overboard through various thru-hulls and 
pump out boxes usually located under the sinks. 
 
To refill the tank, remove the WATER CAPS located on the STBD 
side of the deck.   Attach the hose to the dock spigot and let run for a 
minute before inserting into deck fitting.  Avoid flushing debris from 
the deck into the tank opening.  DO NOT fill water and diesel at the 
same time! 
 
A MANIFOLD to switch tanks is located in the cabinet on the side of 
the navigation station.

 

 

 

Forward THRU-HULL 

AFT THRU-HULL 

Water Tank Selector Valve 

Содержание 1995 Hunter 430

Страница 1: ...1 OPERATION MANUAL VELOCITY 1995 Hunter 430 OWNER HOSTS Kirk and Lisa Knudsen Mount Vernon WA...

Страница 2: ...will enjoy cruising the lovely islands of the Pacific Northwest aboard Velocity The information provided in the manual will help you familiarize yourself with the vessel and its systems If you have qu...

Страница 3: ...A 42 6 Displacement 23 800 Lbs L W L 38 Ballast 7 600 Lbs BEAM 14 Sail Area 839 square ft DRAFT 4 11 Water Capacity 165 Gal CRUISING RPM 3000 Engine 50 HP Yanmar MAST HEIGHT 62 5 Fuel 30 gallon diese...

Страница 4: ...stems 9 Batteries Sanitation Systems 10 Marine Toilet 10 Holding Tank 11 Y Valve 12 Water Systems 12 Fresh Water Tanks 12 Fresh Water Pump 13 Hot Water 13 Shower 13 Galley 13 Stove Oven 13 Refrigerati...

Страница 5: ...L is in the open position lever in line with valve Your thru hull and strainer are located on the aft end of the engine compartment accessible from the aft cabin engine compartment panel under cabin s...

Страница 6: ...the engine catches check your transom for water exiting with the exhaust Allow the engine to warm up by idling for 10 minutes at about 1000 RPM before putting under load Do not hold ignition key in ST...

Страница 7: ...ave your best communicator mid ships to give you distances from the dock It is often hard to judge how close the dock is Calling out distances i e 20 feet 10 feet 4 feet etc will only add to a success...

Страница 8: ...er Therefore monitor the use of onboard electricity carefully with your voltmeter located on the Electrical Panels and turn off electrical devices that are not needed Most breakers are labeled by colo...

Страница 9: ...ter coffeepots space heater water heater refrigerator etc will quickly discharge the house inverter batteries Use these items VERY SPARINGLY Monitor your battery usage very carefully When connected to...

Страница 10: ...attery power alone The electrical outlets will not work under the DC battery system Note Do not change the position of the switches while the engines are running or the alternator diodes will be damag...

Страница 11: ...able catastrophe and an EXPENSIVE FIX to you Empty the tank every other day to avoid this problem The aft HOLDING TANK is located under the floor in the galley The forward HOLDING TANK is located unde...

Страница 12: ...to the holding tank position in respect to Coast Guard regulations Please leave it as is unless there is an emergency Be familiar with the applicable laws concerning dumping sewage directly overboard...

Страница 13: ...efore taking a SHOWER make sure water pressure and shower sump breakers are on To activate the hand held wand turn on water at back of shower head Take only very short boat showers turning off water b...

Страница 14: ...ERATING The HYDRONIC FURNACE provides heat and hot water while pier side or at anchor Turn on the TOGGLE SWITCH located below the circuit breaker panel Set any one of the three THERMOSTATs to the desi...

Страница 15: ...on the arch in the cockpit Ascertain that your breaker is on at the DC breaker panel Refer to the manual normally found in the navigation desk GPS is considered a navigation aid Do not rely on it Com...

Страница 16: ...ss short rests as you are pulling it up The windlass uses a large amount of electrical power so ALWAYS operate the windlass with the engines running Place yourself in position to guide the anchor onto...

Страница 17: ...needs to be released after hoisting the mainsail and reset at the mast on dropping the main Troubleshooting 1 Mainsail resists being raised Check all lines Both reefing lines should be pulled loose a...

Страница 18: ...to bring it up to higher ground NEVER drag it Secure it when leaving as the tides come up very quickly OTHER SAFETY EQUIPMENT SAFETY should be paramount in your daily cruising A MAN OVERBOARD DRILL sh...

Отзывы: