background image

 

Manu details below: 

Main Menu 

Value 

Functions 

 

001-512 

DMX address setting 

 

8/16 channels mode selection 

 

00-99 

Color selective 

 

000-255 

Red intensity 

 

000-255 

Green intensity   

 

000-255 

Blue intensity 

 

000-255 

White intensity   

 

Sound 

 

 

Dimmer curve 1 

 

Dimmer curve 2 

 

Dimmer curve 3 

 

 

DMX CHANNEL MODE

:     

Reduced Mode 

Standard Mode 

Value 

Function 

000-255 

Master dimmer 

000-010 

Off 

011-110 

Strobe        fast-slow 

111-115 

Open   

116-165 

Pulse strobe1    slow-fast 

166-170 

Open 

171-220 

Pulse strobe 2    slow-fast 

221-230 

Open 

231-245 

Random strobe 

246-266 

Open 

 

207-255 

191-206 

184-190 

180-183 

179 

175-178 

174 

<Color Macro >           

Alice Blue

 

Congo Blue 

Dark Steel Blue 

Deep lavender 

Lilac Tint 

Daylight Blue 

Flame Red 

Содержание LED Smart Par1941

Страница 1: ...Instruction Manual PROFESSIONAL SHOW LIGHT LED Smart Par1941 2017 Ver08 28...

Страница 2: ...se and maintenance of this unit Features Multi Colors Color Strobe Electronic Dimming 0 100 DMX 512 protocol Master Slave synchronization LED operation menu with function buttons Daisy Chain Units Tog...

Страница 3: ...e fixture The model is Auto power supply It is workable in 90 250V 50 60Hz Please make sure your unit voltage matches the wall outlet voltage before attempting to operate you fixture Connection to the...

Страница 4: ...his function allows you to control each individual fixtures traits with a standard DMX 512 controller Sound control This function allows you activate fixtures by sound Chart Size mm DMX Mode Operating...

Страница 5: ...mer curve 2 Dimmer curve 3 DMX CHANNEL MODE Reduced Mode Standard Mode Value Function 1 1 000 255 Master dimmer 2 2 000 010 Off 011 110 Strobe fast slow 111 115 Open 116 165 Pulse strobe1 slow fast 16...

Страница 6: ...ange Pale Gold Apricot Bright Blue Primary Green Special lavender Pale Lavender Deep Golden Amber Medium Blue Bright Pink Mauve Dark Green Leaf Green Dark Blue Light Blue Steel Blue Med Blue Green Pea...

Страница 7: ...olor intensity Rigging the fixture Caution Fixture may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do not install the moving head Befor...

Страница 8: ...ronment in which the fixture operates i e smoke fog residue dust dew Parameter Description Power 300W Voltage 110 250V 50 60Hz Workign position Any safe working position Lamp High power 9090 LED 4in1...

Отзывы: