4.

 

Installation 

Refer to the illustrations on page 2 of this manual. 

 

 

The installation must be carried out by a qualified person. 

 

1.

 

Choose a proper location for the sensor. Avoid places where 

temperature changes frequently, e.g. near air conditioners or 

heating devices. Also avoid moving obstructions or objects in the 

detection field of the sensor to prevent unnecessary activation. 

2.

 

The PIR sensor must be installed inside a hole which is max. 

14 mm in diameter. The controller can be installed on the other 

side of the wall, inside a dropped ceiling or, behind a false wall. 

Leave sufficient space (at least 2 cm) around the controller for 

ventilation. 

Notes: 

 

The lead wires of the sensor are ± 20 cm long. When mounting 

the controller on the other side of a wall, drill a hole of at least 

14 mm for the connector and wires to go through. 

 

Make sure the controller is accessible at all times when installing 

inside a dropped ceiling or behind a false wall. However, it should 

be sufficiently protected to avoid accidental touching! 

3.

 

Electrical wiring must be present at the installation location. 

4.

 

Deactivate and remove the fuse of the electric circuit on which 

you want to install the device. 

5.

 

Connect the sensor to the controller 

[2]

. The connector fits only 

one way, do not force. 

6.

 

Set the DIP switches 

[3]

 

 

ON 

OFF 

 

light sensitivity 

< 10 lx 

always 

 

movement sensitivity 

low 

high 

5” 

on-time 

5 seconds 

30” 

on time 

30 seconds 

1’ 

on-time 

1 minute 

3’ 

on-time 

3 minutes 

5’ 

on-time 

5 minutes 

8’ 

on-time 

8 minutes 

 

Note:

 Only the highest selected on-time will be applicable. 

7.

 

Connect the wiring 

[1]

 to the terminals according to the diagram 

on page 2.  

Содержание PIR415U

Страница 1: ...PIR415U MINI PIR MOTION DETECTOR BUILD IN MINI D TECTEUR DE MOUVEMENTS PIR ENCASTRER MINI DETECTOR DE MOVIMIENTOS PIR PARA EMPOTRAR USER MANUAL 3 MODE D EMPLOI 6 MANUAL DEL USUARIO 9...

Страница 2: ...PIR415U V 06 28 04 2015 2 Velleman Inc...

Страница 3: ...opening the cover Touching live wires can cause life threatening electroshocks Have the device installed repaired by qualified personnel There are no user serviceable parts inside the device Refer to...

Страница 4: ...cm long When mounting the controller on the other side of a wall drill a hole of at least 14 mm for the connector and wires to go through Make sure the controller is accessible at all times when insta...

Страница 5: ...ity 93 RH time delay switch 5 s 30 s 1 min 3 min 5 min 8 min light control 3 lx to 2000 lx dimensions visible part 55 64 x 25 64 hidden part controller 2 11 64 x 1 x 1 3 8 weight 1 44 oz Use this devi...

Страница 6: ...ort ne pas l installer et consulter votre revendeur 2 Consignes de s curit Garder l appareil hors de la port e des enfants et des personnes non autoris es Risque d lectrocution lors de l ouverture du...

Страница 7: ...espace d au moins 2 cm autour de l unit pour garantir une ventilation suffisante Remarques Les c bles de connexion du capteur ont une longueur d environ 20 cm Lors du montage percer un trou d au moins...

Страница 8: ...service 93 RH minuteur 5 s 30 s 1 min 3 min 5 min 8 min sensibilit 3 lx 2000 lx dimensions partie visible 22 x 10 mm partie encastr e contr leur 55 x 25 x 35 mm poids 41 g N employer cet appareil qu a...

Страница 9: ...apacitadas y ni os Riesgo de descargas el ctricas al abrir la caja Puede sufrir una peligrosa descarga el ctrica al tocar un cable conectado a la red el ctrica La instalaci n y el mantenimiento deben...

Страница 10: ...aci n suficiente Observaciones Los cables de conexi n del sensor tienen una longitud de aproximadamente 20 cm Durante la instalaci n taladre un agujero de m n 14 mm para el conector de conexi n y los...

Страница 11: ...40 C humedad de funcionamiento 93 RH temporizador 5 seg 30 seg 1 min 3 min 5 min 8 min sensibilidad 3 lx a 2000 lx dimensiones parte visible 22 x 10 mm parte empotrada controlador 55 x 25 x 35 mm peso...

Страница 12: ...rice or a refund at the value of 50 of the retail value in case of a flaw occurred in the second year after the date of purchase and delivery Not covered by warranty all direct or indirect damage caus...

Страница 13: ...ffective si la plainte est justifi e et que la r paration ou le remplacement d un article est jug impossible ou lorsque les co ts s av rent disproportionn s Velleman s autorise remplacer ledit article...

Страница 14: ...pl mentation selon le type de l article et tre mentionn e dans la notice d emploi Garant a de servicio y calidad Velleman Desde su fundaci n en 1972 Velleman ha adquirido una amplia experiencia como d...

Страница 15: ...or un uso incorrecto o un uso ajeno al que est previsto el producto inicialmente como est descrito en el manual del usuario da os causados por una protecci n insuficiente al transportar el aparato da...

Страница 16: ...ts for Velleman manufacturer Other Similar products are found below MK137 MK106 K2622 K DIODE1 72 6514 MK108 K8072 K2634 80 7352 K TF300 MK149 HPS140MK2 VM100 MK123 MK144 MK152 K8086 K RES E12 MK190 M...

Отзывы: