background image

PI300M & PI30024 v2                                                                                         GB 

6

 
13. MAINTENANCE 
 
Very little maintenance is required to keep your inverter operating smoothly. 
Clean the exterior of the device periodically using a damp cloth in order to prevent 
the accumulation of dust and dirt. Tighten the screws on the DC input terminals 
whenever you are cleaning the device. 
 
 

 

14. SPECIFICATIONS 
 

  DC input voltage : 12V / 24V : refer to model label !!! 

  AC Output voltage : 230V 

  Output frequency : 50Hz 

  Continuous output power :   12V input : 275W 

   

24V input : 300W 

  Surge power capacity : 600W 

  Output wave : modified sine wave 

  Efficiency : 90% (typical) 

  No-load current : < 0.65A 

• 

Input current at 100% load : 29.5A for a 12V inverter, 16A for a 24V inverter 

• 

Output current at 100% load : 1.266A 

  Battery-low alarm & shutdown :  10.5 

±

 0.5VDC for 12V input, 21 

±

 1VDC for 

24V input 

  Overheating protection : 55 

±

 5°C 

  Dimensions : 232 x 104 x 58mm 

  Weight : 0,9kg 

• 

Power switch : DC input ON/OFF control 

 
 
15. NOTE 
 
All specifications are typical at nominal input voltage, 50% load and 25°C unless 
otherwise noted. All specifications are subject to change without prior notice. 

WARNING : DO NOT DISASSEMBLE THIS UNIT AS DOING SO MAY CAUSE 
HAZARDOUS VOLTAGES !! RETURN THIS UNIT TO THE DEALER IN CASE 
OF TROUBLE !! 
DO NOT CONNECT ANY INDUCTIVE LOADS WITH THIS DEVICE !! 

 
 

Содержание PI300M

Страница 1: ... WARRANTY HET TOESTEL ZAL WORDEN BESCHADIGD INDIEN U HET OVERBELAST OF ER EEN INDUCTIEVE BELASTING vb koelkast boormachine ventilator OP AANSLUIT DE GARANTIE VERVALT DAN AUTOMATISCH LA SURCHARGE DE L APPAREIL OU LA CONNEXION D UNE CHARGE INDUCTIVE p ex ventilateur réfrigérateur perceuse ENDOMMAGERONT L APPAREIL ET LA GARANTIE SERA INVALIDEE AUTOMATIQUEMENT DIE GARANTIE ERLISCHT UND DER SPANNUNGSWA...

Страница 2: ... cable is 2m Please verify if you have chosen the right operating voltage for both input and output 3 OPERATION When connected to an appliance remember to turn on the inverter before turning on the appliance If the buzzer sounds during operation this indicates that the battery voltage is very low and that the inverter will be disconnected in 5 minutes power switch AC output socket voltage indicato...

Страница 3: ...stranded with a dead battery To avoid over discharging the battery it is advisable to let your engine run for 10 to 20 minutes after every 2 3 hours of using the AC inverter This allows your vehicle s battery to recharge Please remember to connect the wire to the terminal and the wire to the terminal if you choose to use an adapter for a direct connection between the AC inverter and the battery te...

Страница 4: ... not you need this terminal Always use heavy duty yellow and green wiring for this connection In a stationary land based installation the earthing terminal should be connected to a metal earthing stake driven into the ground to a minimum depth of 1 2m One of the battery terminals preferably the negative one should also be connected to the earthing stake if the battery system powering the inverter ...

Страница 5: ...e the AC output voltage you must use an AUTHENTIC RMS VOLT METER Using any other type of voltage measuring device will result in an AC voltage reading that is up to 20 to 30 volts lower than the rated value The reading will only be accurate when using an authentic RMS voltmeter 10 VENTILATION IMPORTANT During operation make sure the fan keeps revolving Check the inverter for possible malfunctions ...

Страница 6: ...e power at once B disconnect all units C check the connected devices D use the units again as soon as any problems concerning the connected devices have been solved When in use for a prolonged period of time the AC output may suddenly be cut off although the battery voltage is still very strong This may be caused by excessive temperatures If this happens please proceed as follows A Switch off the ...

Страница 7: ...tput wave modified sine wave Efficiency 90 typical No load current 0 65A Input current at 100 load 29 5A for a 12V inverter 16A for a 24V inverter Output current at 100 load 1 266A Battery low alarm shutdown 10 5 0 5VDC for 12V input 21 1VDC for 24V input Overheating protection 55 5 C Dimensions 232 x 104 x 58mm Weight 0 9kg Power switch DC input ON OFF control 15 NOTE All specifications are typic...

Отзывы: