![Velleman Personal Scope HPS50 Скачать руководство пользователя страница 46](http://html2.mh-extra.com/html/velleman/personal-scope-hps50/personal-scope-hps50_user-manual_4105284046.webp)
46
HPS50 PersonalScope
TM
Signal position
AC/DC
Gnd
AC/DC
Gnd
Short press:
Choice of input coupling AC
(3)
or
DC
(2)
. Depending on (part of) the signal to be
measured, the input can be connected to the signal
through a direct link or by using a decoupling capa-
citor. Select DC for measuring DC voltage. Press the
“AC/DC”
key to select either AC or DC input
coupling (see indica-tions on the screen).
CHOICE OF INPUT COUPLING
Note:
At time bases of 1s/div and slower, the input
coupling is DC-only.
When measuring the
”ripple”
on a DC voltage :
put the input on AC to limit the measurement to
the AC component of the signal.
SET THE INPUT REFERENCE
Long Press:
Switches the scope input to ground
and stores the trace position as a new dc zero
reference. Use this function to find and set the zero
DC-reference trace on the screen.