Velleman K8008 Скачать руководство пользователя страница 10

10 

Operation modes 

 

Non-retrigger-
able timer 

Push to turn on.  After pre-set time has elapsed, load will turn off.  Pushing the button during on-time 
has no effect. Load will turn off when pushbutton is held down and time elapses. 

Applications :  

General timing. 

 

Turn-on delay 

Turn on delay starts when button is pushed.  When time elapses, load is turned on until 
button is released. 

Applications :  

Prevent cycling of light sources operated by a motion 

detector on porches, front doors, driveways, … 

 

Timer with 
early re-trigger 
prevention 

 turn on with delay1*.  When time elapses, load is turned off and delay2* is enabled.  Load 
cannot be turned on again before delay2 elapses.  Continuous pushing will not switch on the 
load when delay2 elapses. 

Applications :  

Prohibit continuous operation of heating, airco, TV, 

spa, … 

 

Turn-off delay 

Push to turn on load.  When button is released, timer is started.  When time elapses, load is 
turned off.  Repeated push during on-time restarts timer. 

Applications :  

Allow a pump or fan to 

remain on for a while after a sensor detects pre-set level, to prevent cycling. 

 

Interval timer 

As long as the button is pushed, the load will be turned on during delay1*, and turned off during 
delay2* 

Applications :  

Lawn sprinklers, pool pumps, compressor dehydration, ventilation, defrost-

ing,  

 

Blinking circuit 

As long as the button is pushed, the load is turned on and off with a fixed frequency of 1Hz. 

Applications :  

warning lights, buzzers, … 

Содержание K8008

Страница 1: ...MULTIFUNCTION RELAY MODULE K8008 H8008IP 2 14 Different functions including timers switching flashing interval random switching...

Страница 2: ......

Страница 3: ...ontrol with home modular light system K8006 EEPROM for delay time storage in case of power failure On board transient filter for relay contacts or load selectable Suitable for control of incandescent...

Страница 4: ...he eyes Needle nose pliers for bending leads or to hold components in place Small blade and Phillips screwdrivers A basic range is fine For some projects a basic multi meter is required or might be ha...

Страница 5: ...t the PCB surface and carefully solder the leads 2 Make sure the solder joints are cone shaped and shiny 3 Trim excess leads as close as possible to the solder joint REMOVE THEM FROM THE TAPE ONE AT A...

Страница 6: ...W 1 Zener diodes Watch the polarity ZD CATHODE R4 120K 1 2 4 B R5 10K 1 0 3 B D1 1N4148 D2 1N4007 D3 1N4007 D4 1N4007 D5 1N4007 2 Diodes Watch the polarity D CATHODE SW1 DS 4 8 Dip Switch Watch the or...

Страница 7: ...Choose operating voltage For 220 245VAC C4 470nF 400VAC For 110 125VAC C4 1 F 250VAC 12 Capacitor VDR1 VDR 300 VAC 13 VDR IC1 VK8008 Programmed PIC12CE518 15 IC Watch the position of the notch T1 BC54...

Страница 8: ...e sparking Normally this suppressor is put over the relay contacts In some cases it might be necessary to put it on the load eg with very small loads Transient suppressor over the relay contacts Trans...

Страница 9: ...d time elapses Applications General timing Hint use as Toggle mode with a very long delay time This will ensure lights will not remain on forever if forgotten to turn them off Staircase timer Push to...

Страница 10: ...annot be turned on again before delay2 elapses Continuous pushing will not switch on the load when delay2 elapses Applications Prohibit continuous operation of heating airco TV spa Turn off delay Push...

Страница 11: ...tton is released At release the timer is start ed When time elapses output is turned off Pushing again during on time will restart the timer at release of the button Applications Ventilation of restro...

Страница 12: ...has elapsed Push the button again to stop recording The load is turned off and the recording stops The load will blink once To confirm the recorded time press the button briefly within 5 seconds after...

Страница 13: ...13 PCB 19 PCB N L L LOAD C E RY LD P8008 2 VELLEMAN VDR1 7 10 9 8 6 5 4 3 2 1 R9 R8 C5 C1 C2 C3 C4 D1 D2 D3 D4 D5 IC1 A LD1 R1 R2 R3 R4 R5 R6 R7 NC NO COM C2 C1 RY1 1 SW1 T1 ZD1 ZD2 R10...

Страница 14: ...CLR 4 GP0 7 GP1 6 GP2 T0CKI 5 VSS 8 GP5 OSC1 CLKIN 2 VDD 1 IC1 PIC12CE518 R5 10K T1 BC547 R2 47K SW1 SW DIP 4 RY1 VR10V241C LD1 LED3RL D1 1N4148 R6 220 0 6W R10 330K 0 6W C4 470n 250V N 1 nc 2 L 3 L 4...

Страница 15: ......

Страница 16: ...Modifications and typographical errors reserved Velleman Components nv H8008IP 2 2014 rev 2 5 4 1 0 3 2 9 3 1 5 6 2 7 VELLEMAN NV Legen Heirweg 33 B 9890 GAVERE Belgium Europe...

Отзывы: