7
Test
14. Test
Connect the supplied 4k7 resistor between the + and - points of the load.
Connect the Vref point to the DC input.
Set preset RV3 to the middle of its adjustment range.
Connect a DC voltage between 8 and 35V with the V and GND.
Measure between the + and - points of LOAD with a voltmeter (set to read DC voltage).
If everything goes well then the voltage on the output can be adjusted with RV2.
Fig 1.0
Содержание K8004
Страница 10: ...10 PCB 17 PCB P8004 2...
Страница 11: ...11 18 Schematic diagram Schematic diagram T1 D2 D1...