11
Adjustment & use
Further adjustment with the controllers such as K6000, K6002 a. o. :
Connect the output of the sensor (OUT + and -) with the points IN (+ and -) of the controller (this can be
sensor 1 to 4 in the case of K6000)
Plunge the transmitter into the melting ice again and adjust the ZERO trimming potentiometer RV2 so
that the indication for this sensor indicates 0°C, and wait until the indication remains stable.
When using the controller as a room thermostat, you better adjust the maximum indication against body tempera-
ture, using the GAIN trimming potentiometer. It is advisable to verify the temperature at the place of the sensor
with a clinical thermometer.
REMARK : If the sensor is intended to be used for measuring liquid temperatures, it has to be insulated by
enclosing it with silicone or glue.
In case you want higher accuracy above 40°C, then calibrate the sensor in a known source of heat e.g. boiling
water (100°C).
REPEAT THE FULL ADJUSTMENT PROCEDURE AT LEAST ONE MORE TIME!
With temperatures under 0°C and above 70°C it is advisable to not install the electronic circuitry (pcb
with components) near the transmitter.
The specifications are indicative and can differ from one transmitter to another.