etting started

The purpose of this board is to learn how to perform basic measurements with an 

oscilloscope. Most experiments can be performed with any digital storage scope. Some 
experiments can be performed with an analog scope. 
Experiments in this project are performed using the 

Velleman HPS140 Handheld Pocket

 

Scope. All experiments require basic knowledge of terms such as AC and DC voltage, cur-
rent, resistance, etc… 
Make sure to check You Tube as well, it features a short movie for each experiment.

UK

  See the product page on our website for the latest available translated manual.

NL

  Download de laatst beschikbare vertaalde handleiding op de product-pagina van 

onze website.

FR

 Consultez 

la 

fi

 che technique sur notre site web pour la toute dernière version de 

la traduction du mode d'emploi.

D

 

Eine aktuelle Version der deutschen Bedienungsanleitung 

fi

 nden Sie auf der 

Produktseite unserer Website

ES

  Para descargarse el manual del usuario en español más recientes, consulte la 

página del producto en nuestra web.

WARRANTY :

 This product is guaranteed against defects in components and construction from the moment it is purchased and for a period of TWO YEAR starting from the date of 
sale.  This guarantee is only valid if the unit is submitted together with the original purchase invoice. VELLEMAN Ltd limits its responsibility to the reparation of defects 
or, as VELLEMAN components Ltd deems necessary, to the replacement or reparation of defective components. Costs and risks connected to the transport, removal or 
placement of the product, or any other costs directly or indirectly connected to the repair, will not be reimbursed by VELLEMAN components Ltd. VELLEMAN components 
Ltd will not be held responsible for any damages caused by the malfunctioning of a unit.

GARANTIE: 

Ce produit est garanti contre les défauts des composantes et de fabrication au moment de l’achat, et ce pour une période de deux ans à partir de la date d’achat. Cette 
garantie est uniquement valable si le produit est accompagné de la preuve d’achat originale. Les obligations de VELLEMAN S.A. se limitent à la réparation des défauts 
ou, sur seule décision de VELLEMAN S.A., au remplacement ou à la réparation des pièces défectueuses. Les frais et les risques de transport, l’enlèvement et le renvoi 
du produit, ainsi que tous autres frais liés directement ou indirectement à la réparation, ne sont pas pris en charge par VELLEMAN S.A. VELLEMAN S.A. n’est pas 
responsable des dégâts, quels qu’ils soient, provoqués par le mauvais fonctionnement d’un produit.

WAARBORG: 

Dit produkt is gewaarborgd wat betreft gebreken in materialen en vakmanschap op het ogenblik van de aankoop en dit gedurende een periode van TWEE JAAR vanaf 
de aankoop. De waarborg geldt enkel indien het produkt voorgelegd wordt samen met het origineel aankoop bewijs. De verplichtingen van VELLEMAN N.V. beperken 
zich tot het herstellen van defecten of, naar vrije keuze van VELLEMAN N.V., tot het vervangen of herstellen van defecte onderdelen. Kosten en risico’s van transport; het 
wegnemen en terugplaatsen van het produkt, evenals om het even welke andere kosten die rechtstreeks of onrechtstreeks verband houden met de herstelling, worden 
niet door VELLEMAN N.V. vergoed. VELLEMAN N.V. is niet verantwoordelijk voor schade van gelijk welke aard, veroorzaakt door het falen van een product.

GARANTIE: 

Dieses Produkt trägt eine Garantie für fehlerhaftes Material oder Verarbeitungsschäden im Moment des Ankaufs. Sie ist ZWEI JAHRE gültig ab Ankaufsdatum. Die 
Garantie kann nur beansprucht werden, wenn das Produtk mit der Originalrechnung abgegeben wird. Die Verp

fl

 ichtungen der VELLEMAN AG beschränken sich auf die 

Aufhebung der Fehler, oder, nach freier Wahl der VELLEMAN AG, auf den Austausch oder die Reparation der fehlerhaften Teile. Kosten und Risiken des Transports; 
das Entfernen und Wiedereinsetzen des Produkts, sowie alle anderen Kosten die direkt oder indirekt mit der Reparation in Verbindung gebracht werden können, werden 
durch die VELLEMAN AG nicht zurückerstattet. VELLEMAN AG ist nicht für Schäden gleich welcher Art, entstanden aus der fehlerhaften Funktion des Produkt, haftbar.

GARANTÍA: 

El producto está garantizado durante un período limitado de DOS AÑO a partir de la fecha original de compra. La garantía sólo tendrá validez cuando se presente el 
producto con la factura de compra original. VELLEMAN S.A. se limitará a reparar defectos pero es libre de reparar o reemplazar partes defectuosas. VELLEMAN S.A. no 
reembolsará los gastos de transporte o riesgos, ni los gastos para trasladar y reinstalar el producto así como todo otro gasto directamente o indirectamente relacionado 
con la reparación. VELLEMAN S.A. no asumirá ninguna responsabilidad por daños de cualquier naturaleza causados por un producto defectuoso. 

Содержание EDU06

Страница 1: ...LEARN HOW TO GET THE MOST OUT OF YOUR DIGITAL OSCILLOSCOPE EDU06 Oscilloscope Tutor kit HEDU06 By Velleman n v...

Страница 2: ...roduit ainsi que tous autres frais li s directement ou indirectement la r paration ne sont pas pris en charge par VELLEMAN S A VELLEMAN S A n est pas responsable des d g ts quels qu ils soient provoqu...

Страница 3: ...ed AC single phase 11 Connection layout 11 Connection summary 11 Purpose 11 How 11 A little theory 11 Experiment 5 Rectified AC dual phase 12 Connection layout 12 Connection summary 12 Purpose 12 How...

Страница 4: ...e user friendly as they require less setup in order to show a picture of your signal For our experiments we will use a digital scope Waveforms An oscilloscope will mainly display and measure waveforms...

Страница 5: ...to connect the probe to the measuring point in a permanent way so you have your hands free x1 x10 switch When set to x1 the signal is passed on to the scope without attenuation When set to x10 the si...

Страница 6: ...und Thanks to the auto setup mode the unit takes care of V div and time div for you you do not have to do anything In the lower right hand corner the RMS value of the supplied AC voltage is displayed...

Страница 7: ...l input voltage Turn RV1 fully anti clockwise 0V output The trace on our oscilloscope screen remains a flat line as there is no input voltage Next set V div to 50mV div see HPS140 manual for How To in...

Страница 8: ...0 2V div once again restores the display You can continue this process until RV1 is turned fully clockwise In that case we will measure the full input voltage which we also measured in experiment 1 I...

Страница 9: ...ton allows us to toggle between the different markers There are 4 markers two horizontal and two vertical The horizontal markers allow us to measure the amplitude of a displayed signal i e it measures...

Страница 10: ...e number of periods per second Press and hold the upper right hand button until the menu ap pears When the menu appears release the button and press it again a number of times until time mark is displ...

Страница 11: ...n AC voltage to a DC voltage As a diode only conducts the current in one way only one half of the waveform can pass The other half with inverted polarity is blocked As you can see on the screen the tr...

Страница 12: ...HPS140 Handheld Pocket Scope 1 see HPS140 manual for How To instructions Place the probe switch x1 x10 to x1 2 Select 5ms div and 4V div As the switch is still set to single phase rectification the d...

Страница 13: ...ation are gone As opposed to single phase rectification both halves of the sine wave are used Instead of a single diode we use 4 diodes to make a diode bridge Single diode Diode bridge Exercise In exp...

Страница 14: ...SW1 to the correct position 2 Turn on the HPS140 Handheld Pocket Scope It will start up in auto setup mode as always 3 Watch the screen closely You will notice that the trace is almost flat so the cap...

Страница 15: ...rges the capacitor during the falling edge the capacitor supplies current to the circuit If more current is drawn from the supply the ripple will be higher as the capacitor will be drained more so it...

Страница 16: ...that need to be performed for correct DC measurement DC input coupling DC readout DC reference DC input coupling Input coupling needs to be set to DC When set to AC the scope will block any DC signal...

Страница 17: ...ce that the scope will automati cally adapt the V div setting and the measured DC voltage will drop to 2 3 or 1 3 of the original value because of the resistor divider R2 R3 R6 What happens if you swa...

Страница 18: ...splays a square wave The rising edge of the square wave is not perfectly square due to the limitations of this simple two transistor circuit Anyway the resulting waveform is fine for our experiment As...

Страница 19: ...menu Release the button and press it a number of times until Slope is highlighted Wait for the unit to exit he menu Now look at the bottom left hand side of the screen the slope symbol is dis played...

Страница 20: ...he incoming signal to deflect an electron beam which scans from left to right on the screen The electron beam leaves an image on the screen which represents the signal you ve applied Analog signals ar...

Страница 21: ...ings AC coupling DC coupling and GND With AC coupling a capacitor is put in series with the input signal This capacitor blocks any DC com ponent of the signal and passes only AC With DC coupling the c...

Страница 22: ...SK6 SK6 SK7 SK7 SK4 SK4 SK3 SK3 R2 R2 10K 10K R3 R3 10K 10K R6 R6 10K 10K SK5 SK5 SK8 SK8 T2 T2 BC547 BC547 T1 T1 BC547 BC547 C2 C2 1 1 C3 C3 1 1 RV RV3 100K 100K RV RV2 100K 100K LD2 LD2 LED3RL LED3R...

Страница 23: ...gh bandwidth and a sampling frequency of up to 1GHz are giving this unit all the power you need channel oscilloscope spectrum analyser recorder function generator and bode plotter the generator you ca...

Страница 24: ...iarized with AC DC and frequency measurements sine and square waves power supply ripple full and half wave rectifiers oscillators etc Learn what terms such as V div Time div trigger level auto setup e...