4.2 DC voltage
Range
Resolution
Accuracy
200mV
0.01mV
+ 0.05% of rdg + 3 digits
2V
0.1mV
+ 0.1% of rdg + 3 digits
20V
1mV
+ 0.1% of rdg + 3 digits
200V
10mV
+ 0.1% of rdg + 3 digits
1000V
0.1V
+ 0.15% of rdg + 5 digits
Input Impedance : 10M
Ω
4.3 AC Voltage
Range
Resolution
Accuracy
50Hz - 60Hz
40Hz - 1000Hz
2V
0.1mV
+ 0.5 % of rdg + 10 digits
+ 1.0% of rdg + 10 digits
20V
1mV
+ 0.6 % of rdg + 10 digits
+ 1.0% of rdg + 10 digits
200V
10mV
+ 0.6 % of rdg + 10 digits
+ 1.0% of rdg + 10 digits
700V
0.1V
+ 0.8 % of rdg + 15 digits
+ 1.2% of rdg + 15 digits
Input impedance : 2M
Ω
Frequency Range : 40Hz to 1000Hz
Response : TRUE RMS. RMS conversion with Signal Crest Factors Up to 5.
4.4 DC Current
Range
Resolution
Accuracy
Burden Voltage
2mA
0.1µA
+ 0.5% of rdg + 5 digits
110mV/mA
20mA
1µA
+ 0.5% of rdg + 5 digits
15mV/mA
200mA
10µA
+ 0.8% of rdg + 5 digits
5.0mV/mA
10A
1mA
+ 2.0% of rdg + 10 digits
0.03V/A
4.5 AC Current
Range
Resolution
Accuracy
Burden Voltage
2mA
0.1µA
+ 0.8% of rdg + 10 digits
110mV/mA
20mA
1µA
+ 0.8% of rdg + 10 digits
15mV/mA
200mA
10µA
+ 1.2% of rdg + 10 digits
5.0mV/mA
10A
1mA
+ 2.5% of rdg + 10 digits
0.03V/A
Frequency Range : 40 Hz to 1000 Hz
Response : TRUE RMS. RMS Conversion with Signal Crest Factors Up to 5.