DVM94
V. 02 – 02/09/2016
10
©Velleman nv
9.3
DC CURRENT
Do not measure circuits that may contain voltages
> 600 VDC or > 600 VAC
range
resolution
accuracy
2 mA
1 µA
± (0.8 % rdg + 2 digits)
20 mA
10 µA
200 mA
100 µA
± (1.2 % rdg + 2 digits)
10 A
10 mA
± (2.0 % rdg + 5 digits)
Overload protection: F250 mA/600 V, F10 A/600 V fuse
Max. input current: 200 mA for V
Ω
mA jack, 10 A for 10A jack
9.4
AC CURRENT
Do not measure circuits that may contain voltages
> 600 VDC or > 600 VAC
range
resolution
accuracy
2 mA
1 µA
± (1.2 % rdg + 3 digits)
20 mA
10 µA
200 mA
100 µA
± (2.0 % rdg + 3 digits)
10 A
10 mA
± (3.0 % rdg + 7 digits)
Overload protection: F250 mA/600 V, F10 A/600 V fuse
Max. input current: 200 mA for V
Ω
mA jack, 10 A for 10A jack
Frequency range: 40-1000 Hz
Average sensing, calibrated to rms of sine wave
Note: 10 A up to 10 seconds
9.5
RESISTANCE
Do not conduct resistance measurements on live
circuits
range
resolution
accuracy
200 Ω
0.1 Ω
± (0.8 % rdg + 3 digits)
2k Ω
1 Ω
± (0.8 % rdg + 2 digits)
20 kΩ
10 Ω
200 kΩ
100 Ω
2 MΩ
1 kΩ
20 MΩ
10 kΩ
± (1.0 % rdg + 2 digits)