FAULT DIAGNOSIS AT DOOR SYSTEM
Fault
Cause
Control Points
The door never moves.
•
The fuse might have
been thrown out.
•
The system belt may be
broken.
•
The unlocking motor
may be faulty.
•
Unlocking cable may be
broken.
•
Fuse defects should be detected and
corrected
•
The system belt is checked, if it is
broken, it is changed.
•
If the unlocking turns idle and the sound
of buzzing sounds, the wire is broken
and replaced with the new one.
•
If the door is operated from the control,
the button is defective and the change is
made.
The door is opened, the
engine is running but the
door is not opened.
•
Unlocking cable may be
broken.
•
If the unlocking motor is idling and
sounding buzzing, the wire is broken and
replaced with the new one.
After the door is opened, it
is jerking off.
•
The belt turnbuckle
group may be defective.
•
The belt turnbucklng spring may be
broken, a spring change is made.
The door is moving
intermittently when
opening / closing.
•
The reedrelay may be
faulty.
•
The encoder may be
faulty.
•
A magnet is held in front of the reed
relay, and if the lock pulling motor is not
working, the reed roll is faulty.
•
The magnet is held in front of the reed
relay, the encoder is defective if the lock
pull motor is running.
After the sliding door is
commanded, it is going to
open continuously.
•
The reedrelay may be
faulty.
•
A magnet is held in front of the reed
relay, and if the run does not run, the
reed relay is faulty.
When the door closes, the
buzzing sound comes.
•
lock puller may be
faulty.
•
After the door closes, the lock catch is
checked. Since there may be a problem
in the gear, the lock pulling mechanism
is changed.
After the door closes, it
stays outside, behind the
door remains a gap.
•
lock puller may be
faulty.
•
If the magnet is held in front of the reed
relay, there is no movement with the
lock puller, or if the U is broken.
Security wired does not
work
•
Door control unit may
be faulty. If the checks
we've done are not
working on the final
wicket, If the door is not
stalled when you trigger
the white wire (-) in the
main system
installation, the control
unit is faulty.
•
There may be a problem
with the safety wired
electrical installation.
•
Open the door. when the brown cable is
connected with the white cable, if the
door stops and goes back, the wick is
defective. Change roving.
•
If the door stops and does not go back,
when I give the white cable (-) trigger to
the under the door (OPKON cable) under
the front right seat, if the door stops and
goes back, there is a break in the OPKON
cable under the door. Change the opkon
cable.
•
If the fuse still does not work, the
control unit is faulty if the door does not
stop and return when you trigger the
white wire (-) in the main system
installation.