- 11 -
The scheme of fixing cellular polycarbonate to the end-face and doors
5.7.
Fasten hook
49
with self-tapping screws
45
to the right upper crosspiece of
the end, the counter loop of the hook on the diagonal of the upper door so that the
hook fixes the door in the open position (see the picture above).
5.8.
Insert the handles from kit
48
into the
Ø12
holes on the door, having
previously drilled the corresponding holes in the polycarbonate. On the reverse side,
put on the deadbolt and pad, fix the handle and pad with self-tapping screws
45
.
5.9.
Fasten the door latch
51
with self-tapping screws
45
from the inside between the lower and upper Air-doors
so that the doors can be fixed to each other.
To do this, it will be necessary to unscrew the self-
tapping screw in the corner of the door, mount the latch,
and screw the self-tapping screw back.