VMB1BLS
Velbus
–
Legen Heirweg 33, BE-9890 Gavere, Belgium
–
tel. +32 9 384 36 11
–
e-mail: [email protected]
–
www.velbus.eu
PN-VMB1BLS-ed1
ENGLISH
Read and understand this manual and all safety signs before using this appliance. Keep
this manual for future reference.
DESCRIPTION
One-channel blind module (universal mounting).
TECHNICAL SPECIFICATIONS
•
relay contact:
o
230 V AC/ 16 A max.
o
30 V DC / 12 A max.
•
supply voltage: 12..18 V DC
•
power consumption: max. 100 mA
•
dimensions: 72 x 59 x 24 mm
CHARACTERISTICS
•
controlled by Velbus or by directly connected push buttons
•
programmable switch-off time per channel
•
feedback to the input modules
•
LED indications for
o
up and down working modes
o
supply voltage
o
error messages
•
encapsulated for mounting in e.g. shutter casings
•
250 possible addresses
CONTROL
Two buttons:
•
short
press on
↑
or
↓
: shutter up/down until end or until opposite direction pressed
•
continually
pressing
↑
or
↓
: shutter up/down until button released
One button: same principle as two buttons. After each standstill, the motor direction
is reversed. Other actions for use in a Velbus system can be programmed using the
Velbuslink* software.
For general information about the installation and configuration of Velbus, please
consult the
Installation Guide
and other documentation on www.velbus.eu.
LED INDICATIONS
•
LED PS (power supply)
⑫
:
o
continuously on: power supply OK
o
off: power supply not OK
•
LED up
⑬
: flashes while shutter is going up
•
LED down
⑭
: flashes while shutter is going down
•
In case of error, LEDs up
⑬
and down
⑭
will simultaneously flash as follows:
o
2 flashes, break, 2 flashes, etc.: communication error (only if connected to
Velbus data bus and address
≠ FF)
o
3 flashes, break, 3 flashes, etc.: power supply voltage too low
o
4 flashes, break, 4 flashes, etc.: power supply voltage too high
REMARKS
1. ADDRESSING IN A VELBUS INSTALLATION
We recommend addressing the VMB1BLS in advance. To do so, connect the
VMB1BLS to a Velbus (test) installation a
nd use the function “Address management”
with automatic detection in Velbuslink* (for full instructions, see the VMB1BLS
extended user manual on www.velbus.eu > Downloads). Velbuslink will automatically
detect the VMB1BLS when the “up” or “down” push butto
ns are operated (connect
④
or
⑥
to
⑤
).
In case the VMB1BLS was not addressed in advance, this can be done afterwards as
follows:
•
in Velbuslink, right click on a shutter channel of a VMB1BLS that needs to be
addressed and select “Operate”
•
check which of the installed shutters goes up or down
•
you now know which VMB1BLS module in Velbuslink corresponds to this shutter.
2. STANDALONE USE
The VMB1BLS can also be used as a standalone shutter controller (without Velbus
installation). In this case, the VMB1BLS needs only to be powered with 12..18 V
DC/100 mA (connections
⑦
and
⑧
) without connecting the BUS H
⑨
or BUS L
⑩
.
The shutter can directly be operated through the push button(s) connected to
“button up”
④
, “button common”
⑤
and “button down”
⑥
.
3. TERMINATOR
Every Velbus module has a terminator switch or jumper
⑪
. In a typical Velbus
installation
all terminators have to be open except two
. These two closed
terminators are ideally positioned as far as possible from each other.
In a standalone installation of the VMB1BLS, the state of the terminator is of no
importance.
*Version 9.28 or higher
This product complies with all of the relevant European guidelines
and regulations.
CONNECTION DIAGRAMS
Connections
motor up
⑥
push-button common
motor down
⑦
bus supply -
mains
⑧
bus (12..18 V DC)
④
push-button up
⑨
bus data L
⑤
push-button down
⑩
bus data H
Other elements
⑪
terminator
⑬
LED up
⑫
LED PS (power supply)
⑭
LED down
1. VELBUS
230 V AC MOTOR
24 V DC MOTOR
2. STANDALONE
1 PUSH BUTTON
230 V AC MOTOR
24 V DC MOTOR