Installation manual 

Pag. 5 of 26 

rev 06 

In case of replacement of parts, use only original spare parts. 

You should always use personal protective elements to perform actions on the devices. 

The installation and maintenance of air conditioning equipment may be dangerous because within these 

devices there are pressurized refrigerant gas and electrical devices. Therefore the installation, initial start-up 
and subsequent maintenance must be carried out by authorized and qualified personnel only. 

In case of leakage of refrigerant fluid, it is mandatory to ventilate the room, considering also that refrigerant 

fluid when exposed to flame produces toxic gas. 

When refilling the system, after eventual leakage and repair, be sure that inside the refrigerant circuit does 

not enter any substance, such as air, other than the specified refrigerant (R410A). The presence of air or 
other foreign substances in the circuit of refrigerant may cause an abnormal increase of pressure or 
breakage, resulting in personal injury. 

In the case of water spills from sweater circuit, switch off immediately compressor and seawater pump and 

shut off Manual Valves in order to stop the seawater flow. 

During the cold period if the unit is not in use, drain all the hydraulic circuits connected to the unit, as well as 

seawater condenser to prevent them from freezing. 

Some parts of the appliance produce heat during operation. The room installation must ensure adequate 

ventilation and proper heat dissipation. 

3.1.2

 

PROHIBITIONS 

We remember that the use of products that use electricity and water involves the observance of some 

basic safety rules such as: 

It is forbidden the use by children and unassisted disabled  people.

Do not touch the appliance when barefoot or with wet or damp parts of the  body.

It is prohibited any operation before disconnecting the unit from the mains supply by moving the
power switch to "off".

Do not modify safety devices or adjustment without permission and instructions from the
manufacturer.

Do not pull, detach or twist the electrical cables coming from the appliance, even if it is
disconnected from the mains power supply.

It is forbidden to open the access panels to the internal parts of the unit without having first
disconnected the unit from the mains by putting the system power switch to "OFF position".

Do not dispose, abandon or leave within the reach of children the packaging material because it
can be a potential source of danger.

It is forbidden to use refrigerant and water pipes for grounding the  unit.

It is forbidden to disperse R-410A into atmosphere: R410A is a fluorinated greenhouse gas, referred to
in the Kyoto’s Protocol, with a Global Warming Potential (GWP) = 1975.

3.1.3

 

RESPONSIBILITY 

UFLEX S.r.l. disclaims any liability for damage to people, animals or property resulting from the installation, use 
or maintenance improper of the product, or due to failure of compliance with standards and directives 
mentioned in this manual

Содержание Compact 7SC 110 V-60Hz

Страница 1: ...Air Conditioning System Via Milite Ignoto 8 A 16012 Busalla GE Italy Tel 39 0 10 9620 244 239 Fax 39 0 10 9620 333 Web site www ultraflexgroup it eMail service ultraflexgroup it Rev 06 SELF CONTAINED...

Страница 2: ...of all to thank you for deciding to grant your preference to our product We are sure you will be satisfied because it represents the best technology of boat air conditioning By implementing the sugges...

Страница 3: ...y statements or procedures described in this manual that you do not understand contact UFLEX for assistance Phone 39 010 9620 244 or 239 E mail service ultraflexgroup it Keep the manual in a dry locat...

Страница 4: ...be a potential source of danger 3 0 GENERAL NOTICES 3 1 1 SAFETY MEASURES This instruction manual is an integral part of the appliance and therefore must be kept with care and must ALWAYS accompany t...

Страница 5: ...heat during operation The room installation must ensure adequate ventilation and proper heat dissipation 3 1 2 PROHIBITIONS We remember that the use of products that use electricity and water involves...

Страница 6: ...uld cause damage or failure to the system To achieve a successful installation and optimum operating performance carefully follow the instructions provided in this manual The failure to apply the rule...

Страница 7: ...DRAULIC CONNECTIONS The following is a summary of how to install the unit on a sea water circuit and condensate drain CORRECT SYSTEM INSTALLATION The minimum nominal diameter of the connecting pipes s...

Страница 8: ...p is needed to circulate the amount of water required in the heat exchanger This pump is normally centrifugal type and not self priming type so it must be mounted so that it is always at least 20 cm b...

Страница 9: ...ce or repair operations it is essential that each hydraulic connection is provided with the respective shut off valve DRAIN The air treatment involves the separation of condensate water from humidity...

Страница 10: ...ducted allowing the highest air flow rate however in case of restricted space for installation only one nozzle can be ducted while the other shall be closed The diameter of the duct should not be les...

Страница 11: ...Installation manual rev 06 Pag 11 of 26...

Страница 12: ...on area of the unit Air distribution The system need a correct air flow in order to work efficiently It Is therefore important to get the correct distribution without bottlenecks by maintaining the or...

Страница 13: ...onment through an air gas exchanger equipped with aluminium fins having small pitch A filter must be located upstream the exchanger in order to protect it from dust NOTE the filter must be easy reacha...

Страница 14: ...L Line supply voltage 230 VAC 1ph 50 60 Hz 1 L1 power to seawater pump Fuse 5A P remote activation digital input AIN MCU CONTROL LOGIC COMPRESSOR RUN CAPACITOR CP contact for remote compressor activa...

Страница 15: ...eed min med max auto The room thermostat must be installed in a proper position away from heating sources The set point temperature and real value are shown on the thermostat display ON OFF DISPLAY Th...

Страница 16: ...ature sensor fault E5 DC internal Blower fault E7 Comunication error between MCU and room thermostat LP Low pressure commutator alarm HP High pressure commutator alarm LT Evaporator Low temperature on...

Страница 17: ...erall system self contained pumps strainers etc that could overtake the problem must be approved by Uflex otherwise warranty coverage will decline The pump is not self priming any damage incurred due...

Страница 18: ...nd validating procedure please write to the Uflex Team ut ultraflexgroup it or refer to your Uflex service dealer They will get in touch with Uflex Team 7 1 2 Limitations and Exclusions This warranty...

Страница 19: ...Refers to pages containing instructions or information for the installer S Service for the CUSTOMER TECHNICAL ASSISTANCE SERVICE installer Safety pictograms Warning The operation described may cause p...

Страница 20: ...ed limits ventilation speed to a more contained value Automatic operation Medium ventilation speed Maximum ventilation speed Minimum ventilation speed Heating on 8 1 Velair touch control panel with ro...

Страница 21: ...8 Temperature selection 11 8 9 Automatic operation 12 8 10 Operation at medium ventilation speed 12 8 11 Operation at minimum ventilation speed 12 8 12 Operation at maximum ventilation speed 12 8 13...

Страница 22: ...by key From off to on Select one of the 4 operating modes by pressing the relative key Key Operation Display Keep the Heating Cooling key pressed for approx 2 seconds to change the mode between heati...

Страница 23: ...reases by 1 C after one hour and by another degree after two hours in cooling mode 8 12 Operation at maximum ventilation speed Key Operation Display Press and hold the Max Operation key The function b...

Страница 24: ...ed in a range from 9 to 12 K in intervals of 0 1 C Use this adjustment with care and only after having actually detected a discrepancy compared with the actual room temperature using a reliabledevice...

Страница 25: ...Installation manual Pag 25 of 26 rev 06 NOTE...

Страница 26: ...ual Pag 26 of 26 rev 06 UFLEX S r l we reserve the right to make changes to products as it deems necessary or useful without affecting their main feature The technical data presented in this document...

Отзывы: