User Manual VELA S and AS Power Pack
HENSEL Studiotechnik
31
10 Af
Fuse for modeling lamp
The fuse is a general lamp fuse. Make sure that only fuses with
the required value 10 A-quick are used.
Fuse for halogen lamp in flash head
The halogen lamp in the head is protected by a
5 x 20 mm melting fuse.
Caution:
Make sure that depending on the mains voltage the right
modeling lamp is in use and protected by the specified type of
fuse (see table below):
Ue = 230 V
Ue = 115 V*
300W Halogen lamp
1,6 Af quick
3,15 Af quick
650W Halogen lamp
3,15 Af quick
-----
Spare fuses for the power pack
Spare fuses are integrated in the grip rod of the bracket.
Lamp connections
Caution:
Before connecting lamp heads to the VELA AS power pack
check the mains voltage and make sure that the head is
allowed to be operated (115V
∼
/ 230V
∼
/ Bi-Voltage). VELA S
power packs are for 230V operation only.
For flash head connection the heads of the EHT and MH line
with at least 3000 J are available as well as the EHT 3000 E
flash head.
Before starting up the maximum loading of the flash head must
be observed (minimum 3000 Ws).
The admissible load capacity of a flash head will be controlled
by a flash head plug-code. In case of connecting an
inadmissible flash head to the power pack, the code will block
flash release. Only flash head extension cables with the plug-
code must be used. The cables can be ordered with precise
specification from HENSEL Studiotechnik.
Lamp heads / flash heads with halogen lamps, which are not
equipped with a cooling fan, must not be used. During quick
flash sequences, the flashtubes and therefore also the power
pack would be damaged.