background image

               

               

               

 

OFF

 

 

 

 

         

     

    

                                            

    

           

 

                                 

                                       

                

                         

 

                  

                                                       

  

8

9-A

9-B

9-C

9-D

 

www.veko.com 

F20034  REV 0.0

INSTALLATION AND USER MANUAL MDO-O

 Disconnect the mains before installation!

Standard connection: Connect the phase [L] to the 

brown wire, the switch wire [S] the black wire and 

neutral [N] to the blue wire. 

In figure B and C, the order of connection is the same 

as that in figure A.

if power to the MDO-O is switched on, the lighting will 

consequently always be switched on. 

Variant B is not allowed if lighting with an 

inductive nature is switched on [such as 

conventional ballasts]. 

Do not use ‘cold start’ ballasts if the MDO-O is expect-

ed to switch the lighting more than 2 times per day.

Disconnect the mains before installing the MDO-O.

Any work on the 230V mains must be carried out by 

qualified electricians only.

All installation instructions must be followed. If in any 

doubt, please contact the Veko lightsystems Technical 

Department

When connecting the wiring, always take special note of 

corresponding colours. Take all technical specifications 

of the appliance into consideration.

Do not use ‘cold start’ ballasts if the MDO-O is expected 

to switch the lighting more than 2 times per day.

The MDO-O is not certified for alarm purposes. 

For questions about installation send an e-mail to: 

[email protected] 

or call +31 (0)224- 273235.

Nominal voltage: 

Maximum nominal current: 

Own consumption [switched off/on]:

PIR detection angle: 

Turn-off delays: 

Ambient temperature: 

Protection class: 

Factory setting: 

Subject to design changes.

230V ~ ± 10%, 50Hz

6A at cos = 1 

[2A at cos = 0.4]

< 1W / < 4W

Around 130° - 140°

10 secs.- 45 mins. [motion] 

2 mins - 12 mins. [sound]

0-40 °C

IP20

15 mins. [motion] 

6 mins. [sound]

CONNECTING

SAFETY

TECHN. SPECIFICATIONS

For more information on Veko Lightsystems, 

product information and downloads please visit 

www.veko.com

Do you have any questions about installation? 

Send an e-mail to [email protected] or call +31 (0)224 - 273 235

Standard

Can be switched off independently

Standard

Can be switched on independently

Connecting multiple MD-Os in parallel 

in the case of large areas.

Brown

Black

Blue

Brown

Black

Blue

Brown

Black

Blue

Brown

Black

Blue

Brown

Black

Blue

Отзывы: