5.2.2.2
Water supply via direct water connection (automatic filling)
A direct water connection (article no. 152283) can be used as
an option. In this way the steam generator is designed for direct
connection to the water line.
In the event you ordered the direct water connection option (article
no. 152283), proceed as follows:
1.
Switch off the steam generator
2.
Remove the cover (1) and mount the assembly for direct
water connection. Tighten the two provided screws to 2 Nm
and connect the valve reliably to a 3/8'' water connection.
3.
Unscrew the valve connector from the cover plate and con-
nect it to the valve coil.
CAUTION!
Observe the following for automatic filling:
–
Provide a shut-off valve in the water supply line
in the building.
–
Close the shut-off valve during interruptions of
operation and after the end of operation.
–
Regularly check that the connections are leak-
proof and seated securely.
Installation
Connections > Water supply
30.09.2022
Steam generator VEIT SG67
30