![Veinlite EMS PRO Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/veinlite/ems-pro/ems-pro_operation-manual_3848750001.webp)
DIRECTIONS FOR USE
Description
The TransLite Veinlite EMS PRO
®
is a hand-held battery powered illumination device for
finding veins and assisting in vein access. It has two modes of operation: surface
illumination using 8 bright white LEDs and side-transillumination using 12 orange plus
4 red LEDs. Side-transillumination is a patented* technique which enables the Veinlite EMS
PRO to uniformly illuminate a small region of skin and subcutaneous tissue, anywhere on
the body, without any areas of shadow. The side-transillumination technique allows better
visualization of veins than any other transillumination method. The design of the Veinlite
EMS PRO is such that during vein access, the vein is visualized, skin is stretched and the
vein is secured to keep it from rolling.
Copyright 2016 © TransLite, LLC. All rights reserved. These instructions or any part thereof may not be reproduced by
any means, without prior permission of TransLite, LLC.
Manufacturer
TransLite LLC
Vein
lite EMS PRO
®
Warnings
• Veinlite EMS PRO is designed for external examination only.
• To avoid contamination of the device, Veinlite EMS PRO must be used with
the disposable plastic cover.
• To avoid the spread of infection, always change the disposable plastic cover
between patients and wipe the new cover with a germicidal wipe.
• These devices are intended for use only by clinicians trained in performing
vascular access, or under the supervision of a clinician.
• Do not look directly into the LEDs while on.
Warranty Information
The Veinlite EMS PRO has a one year parts and labor warranty. Please provide the serial
number located under the battery or the outside of the box when you contact Translite
LLC for any warranty issues. The warranty is valid only if the Veinlite EMS PRO is used
according to the manufacturer’s instructions. Before returning the Veinlite EMS PRO to
TransLite for repair, you must call or e-mail TransLite to obtain a return authorization
code and shipping information before sending your device. No refunds will be given for
unauthorized shipping.
Explanation of Symbols
Healthcare & Education Centre
The Church, Portland Street
Southport, PR81HU, UK
Tel: +44 1704 544 944
Fax: +44 1704 544 050
This product is covered by Patents.
Patent Numbers: 7,874,698;
7,841,751; 8,032,205; 8,177,808
VEMS PRO DFU Rev 3 1016
EC REP
SYMBOL
EXPLANATION
REF
Model Number
SN
Serial Number
Manufacturer
EC Representative (EU Only)
Do not dispose as unsorted
municipal waste.
EC REP
1
4
FM 633388
Figure 1. Veinlite EMS PRO
Tel: (281) 240 3111
Fax: (281) 240 3122
Intended Use/Indications
Contraindications
• When used for internal
examination
• When used without the
disposable plastic cover
• Examining the skin surface,
finding veins and assisting in
vein access in all patient
populations
• Venous access in patients with a
history of difficult venous access
or fragile veins
• Easier visualization of veins in
dark skinned patients
EMS PRO
[1] Clear Window
[2] On/Off Mode Toggle Switch Button with
Low Battery Light Indicator
[3] Battery Cap
[4] Lanyard Hole
[1]
[2]
[3]
[4]
www.veinlite.com