SD500 Spindle Servo Drive Manual
75
F024.29
(0x581D)
2nd gear proximity
switches equivalent
number of pulses in
one turn
V/F SVC FVC PMVF PMSVC PMFVC
The number of one-turn pulses when the second gear
proximity switch is orientated, which is set automatically
during self-learning. The second gear works when the Xi
terminal is set to 86 and receives a high level, and system will
send to the drive that this is the second gear and the drive runs
as the second gear parameter F24.29/F24.30, otherwise it runs
as the first gear parameter F24.25/F24.07.
0
(0~65535)
STOP
F24.30
(0x581E)
2nd gear spindle
indexing offset
V/F SVC FVC PMVF PMSVC PMFVC
Set spindle indexing offset value.
0
(0~65535)
STOP
Table 4-45
4.15 C0x Group: Monitoring Parameters
Group C00: Basic monitoring
Code (address)
Designation
Code (address)
Designation
C00.00 (0x2100)
Given frequency
C00.20 (0x2114)
Analog output AO
C00.01 (0x2101)
Output frequency
C00.21 (0x2115)
Reserved
C00.02(0x2102)
Output current
C00.22 (0x2116)
Counter value
C00.03 (0x2103)
Input voltage
C00.23 (0x2117)
This power-up running time
C00.04 (0x2104)
Output voltage
C00.24 (0x2118)
Cumulative running time
C00.05 (0x2105)
Mechanical speed
C00.25 (0x2119)
Spindle drive power level
C00.06 (0x2106)
Given torque
C00.26 (0x211A)
Spindle drive rated voltage
C00.07 (0x2107)
Output torque
C00.27 (0x211B)
Spindle drive rated current
C00.08 (0x2108)
Given PID
C00.28 (0x211C)
Software version
C00.09 (0x2109)
PID feedback
C00.29 (0x211D)
PG feedback frequency
C00.10 (0x210A)
Output power
C00.30 (0x211E)
Timer
C00.11 (0x210B)
Bus voltage
C00.31 (0x211F)
PID output value
C00.12 (0x210C)
Module temperature 1
C00.32 (0x2120)
Spindle drive software sub-version
C00.13 (0x210D)
Module temperature 2
C00.33(0x2121)
Encoder feedback angle
C00.14 (0x210E)
Input terminal X ON state (Note)
C00.34 (0x2122)
Z pulse cumulative error
C00.15 (0x210F)
Input terminal Y ON state (Note)
C00.35 (0x2123)
Z-pulse counting
C00.16(0x2110)
Analog AI1 input value
C00.36 (0x2124)
Fault warning code
C00.17 (0x2111)
Analog AI2 input value
C00.37 (0x2125)
Cumulative electricity consumption
(low)