AC80T Tower Crane Purpose VFD Manual
18
F1.20
ACC time 3
0.01
~
650.00s 12.00s
●
F1.21
DEC time 3
0.01
~
650.00s 4.00s
●
F1.22
ACC time 4
0.01
~
650.00s
12.00s
●
F1.23
DEC time 4
0.01
~
650.00s 4.00s
●
F1.24
Emergency stop DEC time
0.01
~
650.00s 10.00s
●
F1.25
FWD/REV dead time
0.0
~
120.0s
0.0s
●
F1.26 Min.
output
frequency
0.00
~
60.00Hz 3.00Hz
●
F1.27
0 speed hold torque
0.0
~
150.0% 100.0%
●
F1.28
0 speed torque hold time
0.0
~
120.0s
120.0s
F1.29
Power failure restart action
seclection
0:Invalid
1:Valid
0
●
F1.30
Power failure restart waiting
time
0.00
~
120.00s 0.50s
●
F1.31
Terminal operation
protection selection
LED “0” digit:
0:Terminal operation
command is invalid
at power-on
1:Terminal operation
command is valid at
power-on
LED “10” digit:
0:Terminal operation
command is invalid
when cut in
1:Terminal operation
command is valid
when cut in
0011
●
F1.32
Inching running frequency
set
0.00
~
Max. frequency
5.00Hz
●
F1.33 Inching
running
ACC
time
0.01
~
650.00s 10.00s
●
F1.34 Inching
running
ACC
time
0.01
~
650.00s 10.00s
●
F1.35 Hopping
frequency
0.00
~
Max. frequency
0.00Hz
●
F1.36
Hopping frequency range
0.00
~
Max. frequency
0.00Hz
●