background image

• If any of the following indications occur during testing, turn 

off the power source to the circuit under test:

• Arcing
• Flame
• Smoke
• Extreme Heat
• Smell of Burning Materials
• Discoloration or Melting of Components

• Read the safety precautions associated with the equipment being 

tested and seek assistance or advice when performing 
unfamiliar tasks.

• Keep your fingers away from the test lead metal probe contacts 

and bus-bars when making measurements. Always grip the 
instrument and test-leads behind the hand guards (molded into 
the probes).

• In the event of electrical shock, ALWAYS bring the victim to 

the emergency room for evaluation, regardless of the victim’s
apparent recovery. Electrical shock can cause an unstable heart
rhythm that may need medical attention.

International Symbols

C o n t rols and Indicators

1.

C l a m p :

Used to measure inductive AC and DC current. 

Opens to 1 1/2” (40 mm).

CAUTION!

The clamp uses a high-tension spring to close the jaw.

DO NOT

allow

fingers or objects to become pinched in the base as jaw closes. 

2.  

Conductor Alignment Marks:

Used to aid in the visual  

alignment of a conductor when measuring inductive ampera g e .
Greatest accura cy is achieved when the conductor inside the clamp 
is centered at the intersection of these marks.

3.  

Hand Guard:

Used as a point of reference for the operator’s safety.

WARNING!

Always keep your hands and fingers behind the hand guards when
measuring current on exposed conductors. Contact may result 
in serious safety.

Introduction

The DL49 is a hand-held, battery powered, digital multimeter with clamp-
on current measuring ca p a b i l i ty. This instrument is ideal for anyone that
needs to make quick, accurate measurements of voltage, resistance, and
AC or DC inductive ampera g e .

Features include

• UL listed 3111-1  
• Six measurement functions

1.  AC inductive amps (to 400 amps)
2.  DC inductive amps (to 400 amps)
3.  AC Volts
4.  DC Volts
5.  Ohms
6.  Continuity (with audible alert)

• Autoranging
• AC amperage peak-hold
• Data hold for volt, ohm, and amperage functions
• Low battery indicator 
• Auto continuity
• Auto power off
• Rugged construction
• Surge protection
• Compact size for easy access to tight areas

Safety Notes

Before using this meter, read all safety information carefully. In 
this manual the word 

"WARNING"

is used to indicate conditions 

or actions that may pose physical hazards to the user. The word 

"CAUTION"

is used to indicate conditions or actions that may 

damage this instrument.

WARNING!

Exceeding the specified limits of this meter is dangerous and can
expose the user to serious or possibly fatal injury.

DO NOT

attempt to measure any voltage that exceeds 600 volts 

with this meter - UEi offers numerous alternatives for measuring
high voltage and current

• Voltages above 60 volts DC or 25 volts AC may constitute a 

serious shock hazard

DO NOT

attempt to use this meter if either the meter or the test 

leads have been damaged. Send unit in for repair by a qualified
repair facility

• Test leads must be fully inserted prior to taking measurements
• Always turn off power to a circuit (or assembly) under test before 

cutting, unsoldering or breaking the current path. Even small
amounts of current can be dangerous

• Always disconnect the live test lead before disconnecting the 

common test lead from a circuit

• When measuring high voltage, disconnect the power source before 

making test lead connections. Connect the test leads to the meter
first then to the circuit under test. Reapply power

DL49-MAN    

P. 1

Содержание dl49

Страница 1: ...1 800 547 5740 Fax 503 643 6322 www ueiautomotive com email info ueiautomotive com DL49 INSTRUCTION MANUAL...

Страница 2: ...nyone that needs to make quick accurate measurements of voltage resistance and AC or DC inductive amperage Features include UL listed 3111 1 Six measurement functions 1 AC inductive amps to 400 amps 2...

Страница 3: ...ange that gives you the best resolution for the function and value measured As the meter seeks the appropriate range the display may briefly display an overload OFL indication or show quickly changing...

Страница 4: ...trical shock and instrument discharge open circuit voltage for the circuit under test must not exceed 600 volts RMS Consider using an optional high voltage probe for high power situations NOTE For all...

Страница 5: ...p your meter dry If it gets wet wipe it dry immediately Liquids damage electronic circuits 3 Whenever practical keep the meter away from dust and dirt which can cause premature wear 4 Although your me...

Страница 6: ...ature Storage temperature Relative humidity storage and use Weight Calibration frequency Ul listing IEC Listing Battery Battery life 7 68 x 3 06 x 1 79 195 x 77 x 46 mm 32 to 113 F 0 to 45 C 4 to 140...

Страница 7: ...warranties of merchantability and fitness for a particular purpose are limited to the express warranty UEi shall not be liable for loss of use of the instrument or other incidental or consequential da...

Отзывы: