17
4 Mounting
WEIGHTRAC 31 • 4 … 20 mA/HART - four-wire
42374-EN-131119
2. Drill the through-holes for the support stands (6) according to the
following drilling plan.
The through-holes in the support stands (6 in each) are suitable
for screws of size M10.
The screws (14) and the washers (15) for fastening on the con-
veyor belt are not included in the scope of delivery.
120 mm
(4.72")
15 mm
(0.59")
150 mm
(5.91")
15 mm (0.59"
)
270 mm (10.63"
)
300 mm (11.81"
)
ø 12 mm
(0.47"
)
Fig. 6: Drilling plan for support stands
3. Use suitable washers (15) for mounting the support stands (6).