![Vega VEGASON 61 Скачать руководство пользователя страница 29](http://html2.mh-extra.com/html/vega/vegason-61/vegason-61_operating-instructions-manual_3883020029.webp)
E
nter the requested parameter via the appropriate keys
,
save your
settings and jump to the next menu item with the
[-
>
]
key
.
A
part from the medium
,
the vessel shape can also in
fl
uence the
measurement
.
T
o adapt the sensor to these measuring conditions
,
this
menu item o
ff
ers di
ff
erent options depending on whether liquid or solid
is selected
.
W
ith
"
L
iquids
"
these are
"
S
torage tank
"
,
"
S
tilling tube
"
,
"
O
pen vessel
"
or
"
S
tirred vessel
"
,
with
"
S
olid
"
,
"
S
ilo
"
or
"
B
unker
"
.
V
essel form
S
torage tank
E
nter the requested parameter via the appropriate keys
,
save your
settings and jump to the next menu item with the
[-
>
]
key
.
T
o suppress
fl
uctuations in the measured value display
,
e
.
g
.
caused
by an agitated product surface
,
a damping can be set
.
T
his time can
be between
0
and
999
seconds
.
K
eep in mind that the reaction time of
the entire measurement will then be longer and the sensor will react to
measured value changes with a delay
.
I
n general
,
a period of a few
seconds is su
ffi
cient to smooth the measured value display
.
D
amping
0
s
E
nter the requested parameter via the appropriate keys
,
save your
settings and jump to the next menu item with the
[-
>
]
key
.
A
linearization is necessary for all vessels in which the vessel volume
does not increase linearly with the level
-
e
.
g
.
with a cylindrical or
spherical tank
-
and the indication or output of the volume is required
.
C
orresponding linearization curves are preprogrammed for these
vessels
.
T
hey represent the correlation between the level percentage
and vessel volume
.
B
y activating the appropriate curve
,
the volume
percentage of the vessel is displayed correctly
.
I
f the volume should
not be displayed in percent but e
.
g
.
in l or kg
,
a scaling can be also set
in the menu item
"
D
isplay
"
.
L
inearisation curve
linear
E
nter the requested parameter via the appropriate keys
,
save your
settings and jump to the next menu item with the
[-
>
]
key
.
V
essel form
D
amping
L
inearisation curve
VEGASON
61
•
4
…
20
m
A
/
HART
four
-
wire
29
6
S
et up with the indicating and adjustment module
PLICSCOM
28778
-
EN
-
081127