background image

2

Contents

VEGAPULS 66 • HART and accumulator pack

47138-EN-210621

Contents

1  For your safety ......................................................................................................................... 3

1.1  Authorised personnel ....................................................................................................... 3

1.2  Appropriate use ................................................................................................................ 3

1.3  Warning about incorrect use ............................................................................................. 3

1.4  General safety instructions ............................................................................................... 3

1.5  EU conformity ................................................................................................................... 4

1.6  NAMUR recommendations .............................................................................................. 4

1.7  Radio license for Europe .................................................................................................. 4

1.8  Radio license for USA ...................................................................................................... 4

1.9  Environmental instructions ............................................................................................... 5

2  Product description ................................................................................................................. 6

2.1  Configuration .................................................................................................................... 6

3 Mounting ................................................................................................................................... 7

3.1  Mounting instructions ....................................................................................................... 7

4  Connecting to power supply ................................................................................................... 8

4.1  Connection of the battery charger .................................................................................... 8

4.2  Wiring plan ....................................................................................................................... 8

5  Set up with the display and adjustment module ................................................................ 10

5.1  Insert display and adjustment module ............................................................................ 10

5.2  Parameter adjustment .................................................................................................... 11

5.3  Menu overview ............................................................................................................... 14

6  Set up with smartphone/tablet, PC/notebook via Bluetooth ............................................. 16

6.1 Preparations ................................................................................................................... 16

6.2 Connecting ..................................................................................................................... 17

6.3  Sensor parameter adjustment ........................................................................................ 17

7 Supplement ............................................................................................................................ 19

7.1  Technical data ................................................................................................................ 19

Information:

This quick setup guide enables quick setup and commissioning of 

your instrument.
You can find supplementary information in the corresponding, more 

detailed Operating Instructions Manual as well as the Safety Manual 

that comes with instruments with SIL qualification. These manuals are 

available on our homepage.

Operating instructions VEGAPULS 66 - HART and power pack: 

Document-ID 40933

Editing status of the quick setup guide: 2021-06-10 

Содержание VEGAPULS 66

Страница 1: ...Quick setup guide Radar sensor for continuous level measurement of liquids VEGAPULS 66 HART and accumulator pack Document ID 47138 ...

Страница 2: ...e display and adjustment module 10 5 1 Insert display and adjustment module 10 5 2 Parameter adjustment 11 5 3 Menu overview 14 6 Set up with smartphone tablet PC notebook via Bluetooth 16 6 1 Preparations 16 6 2 Connecting 17 6 3 Sensor parameter adjustment 17 7 Supplement 19 7 1 Technical data 19 Information This quick setup guide enables quick setup and commissioning of your instrument You can ...

Страница 3: ...otective characteristics of the instrument can be impaired 1 4 General safety instructions This is a state of the art instrument complying with all prevailing regulations and directives The instrument must only be operated in a technically flawless and reliable condition The operator is responsi ble for the trouble free operation of the instrument When measuring aggressive or corrosive media that ...

Страница 4: ... field devices For further information see www namur de 1 7 Radio license for Europe The instrument was tested according to the latest issue of the follow ing harmonized standards EN 302372 Tank Level Probing Radar It is hence approved for use inside closed vessels in countries of the EU Use is also approved in EFTA countries provided the respective standards have been implemented For operation in...

Страница 5: ...s That is why we have introduced an environment management system with the goal of continuously improving company environmental pro tection The environment management system is certified according to DIN EN ISO 14001 Please help us fulfil this obligation by observing the environmental instructions in this manual Chapter Packaging transport and storage Chapter Disposal ...

Страница 6: ...ion class 14 ID numbers instrument documentation 15 Reminder to observe the instrument documentation The type label contains the serial number of the instrument With it you can find the following instrument data on our homepage Product code HTML Delivery date HTML Order specific instrument features HTML Operating instructions and quick setup guide at the time of ship ment PDF Order specific sensor...

Страница 7: ...tructions 1 Distance from the vessel wall 200 mm the antenna should protrude 10 mm into the vessel 500 mm 19 69 ca 10 mm Fig 2 Distance of the antenna to the vessel wall vessel ceiling 2 Note min socket diameter depending on the socket length For further information see chapter Mounting Mounting ...

Страница 8: ...LED yellow charging status 5 Socket for the battery charger The mode switch enables the selection of the following modes 0 sensor off LEDs show the accumulator status 1 2 sensor off LEDs off 3 sensor on for 1 hour after pressing a key delivery status 4 sensor permanently on switching on off via button 5 sensor is switched on every 30 minutes for 3 minutes 6 sensor is switched on every hour for 3 m...

Страница 9: ...9 4 Connecting to power supply VEGAPULS 66 HART and accumulator pack 47138 EN 210621 LED off accumulator is empty ...

Страница 10: ...laced by 90 It is not necessary to interrupt the power supply Proceed as follows 1 Unscrew the housing lid 2 Place the display and adjustment module on the electronics in the desired position and turn it to the right until it snaps in 3 Screw housing lid with inspection window tightly back on Disassembly is carried out in reverse order The display and adjustment module is powered by the sensor an ...

Страница 11: ... display and adjustment module for continuous measured value indication a higher lid with an inspection glass is required 5 2 Parameter adjustment 1 Go to the menu Setup via the display and adjustment module 2 In the menu item Medium you select the medium of your ap plication for example Aqueous solution 3 Select in the menu item Application the vessel the application and the vessel form for examp...

Страница 12: ...pecifications is always the seal surface of the thread or flange The function Echo curve memory makes it possible to save the echo curve at the time of setup This is generally recommended and it is absolutely necessary if you want to use the Asset Management functions If possible the curve should be saved with a low level in the vessel With the adjustment software PACTware and a PC a high resoluti...

Страница 13: ...o the medium surface because if an incorrect too large value is entered the existing level will be saved as a false signal The level would then no longer be detectable in this area If a false signal suppression has already been saved in the sensor the following menu window appears when selecting False signal suppression Delete An already created false signal suppression will be com pletely deleted...

Страница 14: ...0 00 Min adjustment 35 m 0 00 Damping Integration time 0 0 s Current output mode Output character istics 4 20 mA Failure mode 3 6 mA Current output Min Max Min current 3 8 mA Max current 20 5 mA Lock adjustment Released Menu item Default setting Language Order specific Displayed value Filling height in Backlight Switched on Menu item Parameter Default setting Device status Peak value indi cator Di...

Страница 15: ...ting Instrument units Distance in m Temperature in C False signal suppression Linearisation Linear PIN Date Time Actual date Actual time Reset HART mode Address 0 Copy instrument settings Menu item Parameter Device name VEGAPULS 6 Instrument version Hardware and software version Date of manufacture Date Instrument features Order specific characteristics Additional adjustments Info ...

Страница 16: ...On Bluetooth active Off Bluetooth not active The security concept of Bluetooth operation absolutely requires that the default setting of the sensor PIN be changed This prevents unau thorized access to the sensor The default setting of the sensor PIN is 0000 First of all you have to change the sensor PIN in the adjustment menu of the sensor e g to 1111 1 In the adjustment menu go to Additional adju...

Страница 17: ...rch via Bluetooth and start the search function The device auto matically searches for Bluetooth capable devices in the vicinity The message Instrument search running is displayed All devices found are listed in the operating window The search is automatically continued continuously Select in the device list the requested device The message Con necting is displayed For the first connection the ope...

Страница 18: ...18 6 Set up with smartphone tablet PC notebook via Bluetooth VEGAPULS 66 HART and accumulator pack 47138 EN 210621 Fig 8 Example of an app view Setup sensor adjustment App view ...

Страница 19: ...r homepage External battery charger Mains voltage 100 240 V AC Output voltage 24 V DC Max output current short circuit proof 500 mA Load current limitation 70 mA DC plug inside plus outside minus 2 1 mm Integrated accumulator Type Lithium ions Voltage 14 8 V Accumulator capacity 4 7 Wh Charging period from 0 to 100 approx 4 h Operating time after 10 minutes charging of 0 3 h Operating time in mode...

Страница 20: ...ning scope of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change without prior notice VEGA Grieshaber KG Schiltach Germany 2021 Phone 49 7836 50 0 E mail info de vega com www vega com ...

Отзывы: