5 Connecting to power supply
VEGAKON 61 • Transistor (NPN/PNP)
32648-EN-170815
1
2
3
4
5
6
10
9
8
7
1 Housing lid
2 Control lamp (LED)
3 Connection terminals
4 Mode switch (A/B)
5 Type label VEGAKON 61
6 Instrument housing
7 Electrode
8 Cable gland
9 Electronics module
10 Type plate of the electronics module
5.3 Wiring plan
1 2 3 4 5
+
-
Fig. 5: Transistor output
The transistor switches the operating voltage of the electronic module
to the binary input of a PLC or an electrical load. Through different
connections of the consumer (load), PNP or NPN action can be at-
tained.
Caution:
There is no reverse polarity protection. Take note of the polarity of the
output lines.
Floating transistor output