etup procedure
A
fter
VEGAFLEX
65
is connected to voltage supply or after
voltage recurrence
,
the instrument carries out a self
-
check for
approx
.
30
seconds
.
T
he following steps are carried out
:
l
I
nternal check of the electronics
l
I
ndication of the instrument type
,
the
fi
rmware as well as
the sensor
TAG
s
(
sensor designation
)
l
S
tatus byte goes brie
fl
y to fault value
T
hen the current measured value will be displayed and the
corresponding digital output signal will be outputted to the
cable
.
1
)
A
s
VEGAFLEX
65
is a distance measuring instrument
,
the
distance from the sensor to the product surface is measured
.
T
o have the real product level displayed
,
an allocation of the
measured distance to the percentage height must be made
.
T
o
carry out this adjustment
,
the distance is entered with full and
empty vessel
.
I
f these values are not known
,
an adjustment
with the distance values
,
e
.
g
.
10
%
and
90
%
is also possible
.
S
tarting point for these distance speci
fi
cations is always the
seal surface of the thread or
fl
ange
.
W
ith these settings
,
the
real level is calculated
.
F
urthermore the operating range of the
sensor is limited from maximum to the required range
.
T
he real product level during this adjustment is not important
,
because the min
./
max
.
adjustment is always carried out
without changing the product level
.
T
hese settings can be
made ahead of time without the instrument having to be
installed
.
I
n the main menu item
"
B
asic adjustment
"
,
the individual
submenu items should be selected one after the other and
provided with the correct parameter values
.
C
aution
:
I
f there is a separation of di
ff
erent liquids in the vessel
,
e
.
g
.
by
condensation
,
VEGAFLEX
65
will always detect the medium
with the higher dielectric
fi
gure
(ε
r
).
K
eep in mind that interfaces can cause faulty measurements
.
I
f you want to measure the total height of both liquids reliably
,
please contact our service department or use an instrument
specially designed for interface measurement
.
1
)
T
he values correspond to the actual measured level as well as to the set
-
tings already carried out
,
e
.
g
.
default setting
.
S
witch on phase
P
arameter adjustment
24
VEGAFLEX
65
•
F
oundation
F
ieldbus
6
S
et up with the indicating and adjustment module
PLICSCOM
31848
-
EN
-
080716