4
M
ounting
4
.
1
G
eneral instructions
I
n general
,
VEGACAP
66
can be mounted in any position
.
T
he
instrument must be mounted in such a way that the probe is at
the height of the requested switching point
.
W
ith screwed versions
,
the housing must not be used for
screwing in
!
T
ightening can cause damages on the locking
piston of the housing
.
T
o screw in
,
use the hexagon above the thread
.
U
se the recommended cable
(
see chapter
"
C
onnecting to
power supply
"
)
and tighten the cable gland
.
Y
ou can give your
VEGACAP
66
additional protection against
moisture penetration by leading the connection cable down
-
ward in front of the cable entry
.
R
ain and condensation water
can thus drain o
ff
.
T
his applies mainly to mounting outdoors
,
in
areas where moisture is expected
(
e
.
g
.
by cleaning processes
)
or on cooled or heated vessels
.
F
ig
.
3
:
M
easures against moisture penetration
T
he process
fi
tting must be sealed if there is gauge or low
pressure in the vessel
.
B
efore use
,
check if the seal material is
resistant against the measured product and the process
temperature
.
S
witching point
H
andling
M
oisture
P
ressure
/
V
acuum
10
VEGACAP
66
-
with relay output
M
ounting
30020
-
EN
-
050920