16
9 Supplement
External housing • VEGACAP, VEGACAL
31085-EN-161104
Ambient temperature on the sensor
housing - with BNC plug connection
-50 … +100 °C (-58 … +212 °F)
Ambient temperature on the connection
cable
-50 … +150 °C (-58 … +302 °F)
Ambient, storage and transport temperature on the instrument housing
Ʋ without PLICSCOM
-40 … +80 °C (-40 … +176 °F)
Ʋ with PLICSCOM
1)
-20 … +70 °C (-4 … +158 °F)
Electromechanical data
Cable entry/plug
2)
Ʋ Instrument housing
– 1 x cable gland M20 x 1.5 (cable: ø 6 … 12 mm), 2 x
blind plug M20 x 1.5
or:
– 1 x closing cap ½ NPT, 2 x blind plug ½ NPT
or:
– 1 x plug (depending on the version), 2 x blind plugs
M20 x 1.5
Ʋ Housing base
– 1 x cable entry M20 x 1.5 (cable: ø 6 … 12 mm)
Spring-loaded terminals
for wire cross-section up to 2.5 mm² (AWG 14)
Electrical protective measures
Protection rating
Ʋ Metal housing: IP 68 (NEMA Type 6P) IP 68 (10 bar) (NEMA Type 6P)
Ʋ Metal housing: IP 67 (NEMA Type 4X) IP 67 (NEMA Type 4X)
Ʋ BNC plug
IP 54 (NEMA Type 3S)
Ʋ Instrument housing - Instrument
socket
IP 66/IP 67 (NEMA Type 4X)
1)
Only with VEGACAL.
2)
Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.