Vega VEGABAR 81 Скачать руководство пользователя страница 5

5

2 Product description

VEGABAR 81 • Slave sensor for electronic differential pressure

48050-EN-160212

2  Product description

2.1  Configuration

The type label contains the most important data for identification and 

use of the instrument:

2

1

13

14

15

12

10

11

5

3

6

4

7

8

9

Fig. 1: Layout of the type label (example)
1  Instrument type

2  Product code

3  Field for approvals

4  Power supply and signal output, electronics

5  Protection rating

6  Measuring range

7  Permissible process pressure

8  Material, wetted parts

9  Order number

10  Serial number of the instrument

11  Data-Matrix-Code for smartphone app

12  Symbol of the device protection class

13  ID numbers, instrument documentation

14  Reminder to observe the instrument documentation

15  SIL identification

The type label contains the serial number of the instrument. With it 

you can find the following instrument data on our homepage:

• 

Product code (HTML)

• 

Delivery date (HTML)

• 

Order-specific instrument features (HTML)

• 

Operating instructions, quick setup guide and Safety Manual at the 

time of shipment (PDF)

• 

Test certificate (PDF) - optional

Go to 

www.vega.com, "

VEGA Tools

" and "

Instrument search

". Enter 

the serial number.

Alternatively, you can access the data via your smartphone:

• 

Download the smartphone app "

VEGA Tools

" from the "

Apple App 

Store

" or the "

Google Play Store

"

• 

Scan the Data Matrix code on the type label of the instrument or

• 

Enter the serial number manually in the app

Type label

Serial number - Instru-

ment search

Содержание VEGABAR 81

Страница 1: ...Quick setup guide Pressure transmitter with metallic measuring cell VEGABAR 81 Slave sensor for electronic differential pres sure With SIL qualification Document ID 48050...

Страница 2: ...n example 11 5 Set up with the display and adjustment module 5 1 Insert display and adjustment module 12 5 2 Parameter adjustment 13 6 Supplement 6 1 Technical data 18 Information This quick setup gui...

Страница 3: ...fill or damage to system components through incorrect mounting or adjustment Also the pro tective characteristics of the instrument can be influenced 1 4 General safety instructions This is a high tec...

Страница 4: ...mation in chapter Functional safety SIL The instrument meets the specifications of IEC 61508 2010 Edi tion 2 It is qualified for single channel operation up to SIL2 The instrument can be used homogene...

Страница 5: ...tion class 13 ID numbers instrument documentation 14 Reminder to observe the instrument documentation 15 SIL identification The type label contains the serial number of the instrument With it you can...

Страница 6: ...the following functions Ventilation of the electronics housing Atmospheric pressure compensation with relative pressure meas uring ranges Turn the housing so that the filter element points downward a...

Страница 7: ...s can result see following examples Data Application Level measurement Medium Water Vessel height 12 m hydrostatic pressure 12 m x 1000 kg m3 x 9 81 m s2 117 7 kPa 1 18 bar Superimposed pressure 1 bar...

Страница 8: ...Nominal measuring range Slave 1 bar Turn Down 1 bar 0 050 bar 20 1 The measuring result level pressure difference as well as measured value Slave static or superimposed pressure are outputted by the...

Страница 9: ...block is pluggable and can be removed from the electronics To do this lift the terminal block with a small screwdriver and pull it out When reinserting the terminal block you should hear it snap in Yo...

Страница 10: ...the supplied cable gland 10 Connection cable to Master see steps 3 to 8 11 Screw the housing lid back on The electrical connection is finished 4 2 Single chamber housing The following illustration app...

Страница 11: ...g 5 Connection example electronic differential pressure 1 Master sensor 2 Slave sensor 3 Connection cable 4 Supply and signal circuit Master sensor Connection between master and sensor is carried out...

Страница 12: ...s each displaced by 90 It is not necessary to interrupt the power supply Proceed as follows 1 Unscrew the housing lid 2 Place the display and adjustment module on the electronics in the desired positi...

Страница 13: ...ss is required 5 2 Parameter adjustment A parameter change with SIL qualified instruments must always be carried out as follows Unlock adjustment Change parameters Lock adjustment and verify modified...

Страница 14: ...level 3 Select in the menu item Units the adjustment unit of the instru ment e g bar 4 Depending on the application carry out the adjustment e g in the menu items Min adjustment and Max adjustment VE...

Страница 15: ...anging the product level These settings can be made ahead of time without the instrument having to be installed 1 Set the requested damping of the output signal in the menu item Damping 2 Select the o...

Страница 16: ...on correction SIL 0 00 bar Adjustment SIL Distance with density and interface 1 00 m Zero Min adjustment 0 00 bar 0 00 Span Max adjustment Nominal measuring range in bar 100 00 Damping SIL Integration...

Страница 17: ...000 Date Time Actual date Actual time Copy instrument set tings Special parameters No reset Scaling Scaling size Volume in l Scaling format 0 corresponds to 0 l 100 corresponds to 0 l Current output C...

Страница 18: ...d terminals Massive wire stranded wire 0 2 2 5 mm AWG 24 14 Stranded wire with end sleeve 0 2 1 5 mm AWG 24 16 Interface to the Master sensor Data transmission Digital I C Bus Connection cable to the...

Страница 19: ...19 Notes VEGABAR 81 Slave sensor for electronic differential pressure 48050 EN 160212...

Страница 20: ...of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change without prior n...

Отзывы: